Emerson Rosemount 2088 Quick Start Manual

Emerson Rosemount 2088 Quick Start Manual

Pressure transmitters
Hide thumbs Also See for Rosemount 2088:

Advertisement

Quick Start Guide
00825-0100-4690, Rev FD
September 2017
Rosemount
2088, 2090P, and 2090F
Pressure Transmitters
®
with 4–20 mA HART
and 1–5 Vdc HART Low Power
Protocol

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Rosemount 2088 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Emerson Rosemount 2088

  • Page 1 Quick Start Guide 00825-0100-4690, Rev FD September 2017 ™ Rosemount 2088, 2090P, and 2090F Pressure Transmitters ® with 4–20 mA HART and 1–5 Vdc HART Low Power Protocol...
  • Page 2: Table Of Contents

    Quick Start Guide NOTICE This installation guide provides basic guidelines for the Rosemount 2088 and 2090 transmitters. It does not provide instructions for configuration, diagnostics, maintenance, service, troubleshooting, Explosion-proof, Flameproof, or intrinsically safe (I.S.) installations. Refer to the Rosemount 2088/2090 Reference Manual more instruction and low power output.
  • Page 3: Mount The Transmitter

    Quick Start Guide September 2017 1.0 Mount the transmitter 1.1 Rosemount 2088 Mount directly to the impulse line without using an additional mounting bracket or mount directly to a wall, panel, or two-inch pipe using an optional mounting bracket. 1.2 Rosemount 2090P Mount directly to the process pipe using an existing weld spud, or have a skilled welder install a new weld spud using a TIG welder.
  • Page 4 September 2017 Quick Start Guide Figure 2. Panel and Pipe Mounting Panel mount Pipe mount 1.4 Liquid flow applications 1. Place taps to the side of the line. 2. Mount beside or below the taps. 1.5 Gas flow applications 1. Place taps in the top or side of the line. 2.
  • Page 5: Set The Jumpers

    Quick Start Guide September 2017 1.8 Gage transmitter orientation The low side pressure port (atmospheric reference) on the gage transmitters with aluminum housings are located in the neck of the transmitter, behind the housing. The vent path is 360° around the transmitter between the housing and sensor.
  • Page 6: Connect The Wiring And Power

     Note Installation of the transient protection terminal block does not provide transient protection unless the Rosemount 2088 case is properly grounded. Note Do not connect the powered signal wiring to the test terminals. Power could damage the test diode in the test connection. Twisted pair cable yields best results. For high EMI/RFI environments, shielded twisted pair cable should be used.
  • Page 7: Power Supply

    ≥ 250Ω A. R B. 24 Vdc supply C. Current meter Figure 6. Field Wiring for Rosemount 2088 — Low Power Option Code N A. Voltmeter B. Power supply 3.1 Power supply The dc power supply (Option S: 10.5–42.4 V and Option N: 6–14 V) should provide power with less than two percent ripple.
  • Page 8: Verify Configuration

    September 2017 Quick Start Guide Figure 7. Maximum Loop Resistance = 43.5 (Power Supply Voltage – 10.5) 1387 1000 Operating region 10.5 42.4 Voltage (Vdc) The Field Communicator requires a minimum loop resistance of 250Ω for communication. 4.0 Verify configuration A check () indicates the basic configuration parameters.
  • Page 9: Trim The Transmitter

    Quick Start Guide September 2017 Function HART Fast Key sequence Scaled D/A Trim (4–20 mA Output) 1, 2, 3, 2, 2 Self Test (Transmitter) 1, 2, 1, 1 Sensor Info 1, 4, 4, 2 Sensor Trim (Full Trim) 1, 2, 3, 3 Sensor Trim Points 1, 2, 3, 3, 5 Status...
  • Page 10: Safety Instrumented Systems

    September 2017 Quick Start Guide 6.0 Safety instrumented systems The following section applies to Rosemount 2088 Transmitters used in SIS applications. Note Transmitter output is not safety-rated during the following: configuration changes, multidrop, loop test. Alternative means should be used to ensure process safety during transmitter configuration and maintenance activities.
  • Page 11: Specifications

    Reference Manual for additional information. 6.4 Reference Specifications The Rosemount 2088 must be operated in accordance to the functional and performance specifications provided in the Rosemount 2088 Reference Manual. 1. This tests for compliance voltage problems such as a low loop power supply voltage or increased wiring resistance.
  • Page 12 September 2017 Quick Start Guide Failure rate data The FMEDA report includes failure rates. This report is available at Emerson.com/Rosemount. 2088 safety failure values Safety accuracy: 2.0% Safety response time: 1.5 sec Product life 50 years – based on worst case component wear-out mechanisms – not based on wear-out process wetted materials.
  • Page 13: Product Certifications

    +70 °C); Type 4x Special Condition for Safe Use (X): 1. The Rosemount 2088 Transmitter with the transient terminal block (Option code T1) will not pass the 500 Vrms dielectric strength test and this must be taken into account during installation.
  • Page 14 September 2017 Quick Start Guide Europe ED ATEX Flameproof Certificate: KEMA97ATEX2378X Standards: EN60079-0:2012 + A11:2013, EN60079-1:2014, EN60079-26:2015 ≤ T ≤ Markings: G Ex db IIC T6…T4 Ga/Gb, T6(–60 °C +70 °C), ≤ T ≤ T4/T5(–60 °C +80 °C) Special Conditions for Safe Use (X): 1.
  • Page 15 4. Cable entries and blanking plugs must be suitable for the ambient range of the apparatus and capable of withstanding a 7 J impact test. 5. The Rosemount 2088/2090 sensor module must be securely screwed in place to maintain the ingress protection of the enclosure.
  • Page 16 September 2017 Quick Start Guide Special Condition for Safe Use (X): 1. When fitted with a transient suppression terminal block, the Rosemount 2088 is incapable of passing the 500 V isolation test. This must be taken into account during installation.
  • Page 17 Capacitance C 0.012 μF Special Conditions for Safe Use (X): 1. When fitted with a transient suppression terminal block, the Rosemount 2088 is incapable of passing the 500 V isolation test. This must be taken into account when installing the equipment.
  • Page 18 September 2017 Quick Start Guide Special Conditions for Safe Use (X): 1. The enclosure may be made of aluminum alloy and given a protective polyurethane paint finish; however, care should be taken to protect it from impact or abrasion if located in a zone 0 environment.
  • Page 19 Quick Start Guide September 2017 Japan E4 Japan Flameproof Certificate: TC20869, TC20870 Markings: Ex d IIC T5 Technical Regulations Customs Union (EAC) EM EAC Flameproof Certificate: RU C-US.GB05.B.01197 ≤ T ≤ ≤ T ≤ Markings: Ga/Gb Ex d IIC T4/T6 X, T4(–40 °C +80 °C), T6(–40 °C +40 °C) Special Condition for Safe Use (X):...
  • Page 20 September 2017 Quick Start Guide Table 6. Thread Adapter Thread Sizes Female thread Identification mark M20 1.5–6H –14 NPT –14 NPT Special Conditions for Safe Use (X): 1. When the thread adapter or blanking plug is used with an enclosure in type of protection increased safety “e”...
  • Page 21 A copy of the EU Declaration of Conformity can be found at the end of the Quick Start Guide. The most recent revision of the EU Declaration of Conformity can be found at Emerson.com/Rosemount. Ordinary Location Certification As standard, the transmitter has been examined and tested to determine that the...
  • Page 22 September 2017 Quick Start Guide Europe ED ATEX Flameproof Certificate: KEMA97ATEX2378X Standards: EN60079-0:2012 + A11:2013, EN60079-1:2014, EN60079-26:2015 ≤ T ≤ Markings: G Ex db IIC T6…T4, T6(–60 °C +70 °C), ≤ T ≤ T4/T5(–60 °C +80 °C) Special Conditions for Safe Use (X): 1.
  • Page 23 4. Cable entries and blanking plugs must be suitable for the ambient range of the apparatus and capable of withstanding a 7 J impact test. 5. The Rosemount 2088/2090 sensor module must be securely screwed in place to maintain the ingress protection of the enclosure.
  • Page 24 Capacitance C 0.012 μF Special Conditions for Safe Use (X): 1. When fitted with a transient suppression terminal block, the Rosemount 2088 is incapable of passing the 500 V isolation test. This must be taken into account during installation. 2. The enclosure may be made of aluminum alloy and given a protective polyurethane paint finish;...
  • Page 25 Quick Start Guide September 2017 Special Conditions for Safe Use (X): 1. The ambient temperature is as follows: Temperature class –20 °C ≤ T ≤ 80 °C –20 °C ≤ T ≤ 40 °C 2. The earth connection facility on the enclosure should be connected reliably. 3.
  • Page 26 September 2017 Quick Start Guide 7. End users are not permitted to change any internal components, but to settle the problem in conjunction with the manufacturer to avoid damage to the product. 8. During installation, use and maintenance of this product, observe the following standards: GB3836.13-2013, GB3836.15-2000, GB3836.16-2006, G3836.18-2010, GB50257-2014.
  • Page 27 Quick Start Guide September 2017 Table 12. Thread Adapter Thread Sizes Male thread Identification mark 1.5– 6H –14 NPT –14 NPT –14 NPT –14 NPT Female thread Identification mark M20 1.5–6H –14 NPT –14 NPT PG 13.5 PG 13.5 Special Conditions for Safe Use (X): 1.
  • Page 28: Eu Declaration Of Conformity

    September 2017 Quick Start Guide Figure 9. Rosemount 2088 and 2090 Declaration of Conformity EU Declaration of Conformity No: RMD 1010 Rev. L Rosemount, Inc. 8200 Market Boulevard Chanhassen, MN 55317-9685 declare under our sole responsibility that the product, Rosemount Pressure Transmitters 3051P, 2051G, 2088, and 2090 manufactured by, Rosemount, Inc.
  • Page 29 Quick Start Guide September 2017 EU Declaration of Conformity No: RMD 1010 Rev. L EMC Directive (2014/30/EU) Harmonized Standards: EN 61326-1:2013, EN 61326-2-3:2013 ATEX Directive (2014/34/EU) BAS00ATEX1166X - Intrinsic Safety Certificate Equipment Group II Category 1 G Ex ia IIC T4 Ga Harmonized Standards: EN60079-0:2012 + A11:2013, EN60079-11:2012 BAS00ATEX3167X - Type n Certificate...
  • Page 30 September 2017 Quick Start Guide EU Declaration of Conformity No: RMD 1010 Rev. L ATEX Notified Bodies DEKRA (KEMA) [Notified Body Number: 0344] Utrechtseweg 310, 6812 AR Arnhem P.O. Box 5185, 6802 ED Arnhem The Netherlands Postbank 6794687 SGS Baseefa Limited [Notified Body Number: 1180] Rockhead Business Park Staden Lane Buxton, Derbyshire...
  • Page 31 Quick Start Guide September 2017 Rosemount 2088, 2090F, and 2090 China RoHS List of Rosemount 2088, 2090F, and 2090 Parts with China RoHS Concentration above MCVs / Hazardous Substances Hexavalent Polybrominated Polybrominated Part Name Lead Mercury Cadmium Chromium biphenyls diphenyl ethers...
  • Page 32 Enquiries@AP.EmersonProcess.com Standard Terms and Conditions of Sale can be found on the Terms and Conditions of Sale page. The Emerson logo is a trademark and service mark of Emerson Middle East and Africa Regional Office Electric Co. Emerson Automation Solutions Rosemount and Rosemount logotype are trademarks of Emerson.

This manual is also suitable for:

Rosemount 2090pRosemount 2090f