Appendix B: Product Certifications
March 2014
I5
Canadian Standards Association (CSA)
All CSA hazardous approved transmitters are certified per ANSI/ISA 12.27.01-2003.
C6
European certifications
ED
I1
86
Intrinsically Safe and Non-Incendive
Certificate: 0V9A7.AX
Standards Used: FM Class 3600 - 1998, FM Class 3610 - 2010, FM Class 3811 - 2004, FM
Class 3810 - 1989.
Markings: Intrinsically safe for use in Class I, Division 1, Groups A, B, C, D; Class II, Division
1, Groups E, F, and G; and Class III, Division 1
Temperature Code: T4 (T
Non-incendive for Class I, Division 2, Groups A, B, C, and D.
Temperature Code: T4 (T
For input parameters see control drawing 02088-1018.
Explosion-Proof, Intrinsically Safe, Dust Ignition-Proof and Class I Division 2
Certificate: 1015441
Standards Used: CAN/CSA Std. C22.2 No. 0-M91, CSA Std. C22.2 No. 25 - 1966, CSA Std.
C22.2 No. 30 - M1986, CAN/CSA Std. C22.2 No. 94 - M91, CSA Std. C22.2 No. 142
- M1987, CAN/CSA Std. C22.2 No. 157-92, CSA Std. C22.2 No. 213 - M1987, ANSI/ISA
12.27.01-2003.
Markings: Explosion-proof for Class I, Division 1, Groups B, C, and D. Dust-Ignition-Proof
for Class II, Division 1, Groups E, F, G, Class III. Suitable for Class I, Division 2, Groups A, B,
C, and D. Intrinsically Safe for Class I, Division 1, Groups A, B, C, and D.
Temperature Code: T3C. Enclosure Type 4X. Factory sealed. Single Seal. See control
drawing 02088-1024.
ATEX Flameproof
Certificate: KEMA97ATEX2378X
Standards Used: EN60079-0:2006, EN60079-1:2007, EN60079-26:2007
Markings:
II
1
/
G
2
Ex d IIC T6 (-40 °C  T
 40 °C); T4 (-40 °C  T
a
1180
Special Conditions for Safe Use (X):
1. This device contains a thin wall diaphragm. Installation, maintenance, and use shall
take into account the environmental conditions to which the diaphragm will be
subjected. The manufacturer's instructions for installation and maintenance shall be
followed in detail to assure safety during its expected lifetime.
2. For information on the dimensions of the flameproof joints the manufacturer shall be
contacted.
ATEX Intrinsic Safety
Certificate: BAS00ATEX1166X
Standards Used: EN60079-0:2012, EN60079-11:2012
Markings:
II 1G
Ex ia IIC T5 Ga (-55 °C  T
a
Ex ia IIC T4 Ga (-55 °C  T
a
1180
= 70 °C) in accordance with Rosemount drawing 02088-1018.
a
= 85 °C), Enclosure Type 4X.
a
 80 °C)
a
 40 °C)
 70 °C)
Reference Manual
00809-0100-4108, Rev BA
Product Certifications