Appendix A: Specifications and Reference Data
March 2014
Table 2. Rosemount 2088 Pressure Transmitter ordering information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is manufactured after receipt of order and is subject to additional delivery lead time.
Configuration
Standard
C9
Software configuration
Manifold assemblies
Standard
(5)(6)
Assemble to Rosemount 306 integral manifold
S5
Calibration accuracy
Standard
(10)
0.065% accuracy to 10:1 turndown
P8
Water approval
Standard
(11)
NSF drinking water approval
DW
Surface finish
Standard
Q16
Surface finish certification for sanitary remote seals
Toolkit total system performance reports
Standard
QZ
Remote Seal System Performance Calculation Report
HART Revision configuration
Standard
(9)(12)
Configured for HART Revision 5
HR 5
(9)(13)
Configured for HART Revision 7
HR7
Typical model number: 2088 G 2 S 22 A 1 B4 M5
(1) HART Revision 5 is the default HART output. The 2088 with selectable HART can be factory or field configured to HART Revision 7. To order HART Revision
7 factory configured, add option code HR7.
(2) Materials of Construction comply with recommendations per NACE MR0175/ISO 15156 for sour oil field production environments. Environmental limits
apply to certain materials. Consult latest standard for details. Selected materials also conform to NACE MR0103 for sour refining environments.
(3) Not available with low-power Transmitter Output code N.
(4) Not available with Alloy C-276, Material of Construction code 33.
1
(5) Use
/
2
- 14 NPT Female Process Connection code A.
(6) "Assemble-to" items are specified separately and require a completed model number.
(7) Only available with Conduit Thread code 4
(8) Only available with 4-20 mA HART Output (Output Code A).
(9) Select Configuration Buttons (option code D4 or DZ) or Local Operator Interface (option code M4) if local configuration buttons are required.
(10) Requires Transmitter Output code S with either Materials of Construction code 22 or 23.
(11) Requires Materials of Construction code 22 with Process Connection code A.
(12) Configures the HART output to HART Revision 5. The device can be field configured to HART Revision 7 if needed.
(13) Configures the HART output to HART Revision 7. The device can be field configured to HART Revision 5 if needed.
80
Reference Manual
00809-0100-4108, Rev BA
Appendix A: Specifications and Reference Data
Standard
Standard
Standard
Standard
Standard
Standard
Standard