Mitel SMarT-1 FBC Installation & Programming Manual page 17

Fax business controller
Table of Contents

Advertisement

Valid and Invalid Entries
Special Functions
8380-377-115-NQ
Issue 1, January 1997
Each time you enter a valid command, the Controller will automatically space to the next
entry point waiting for more input. If you make an invalid entry, you will see a question
mark:
?
(indicates an incorrect entry)
>
(indicates a correct entry)
Special Function Commands allow access to specific data in the Controller. You must be
in the programming mode to use these commands.
Commands
902
Data confirmation mode. After each 3 digit prefix
the Controller will display programmed data
961
Display Power-on Counter (Displays the number
of times that the FBC has been powered on since it
was last * initialised)
Display Route and Line peg data
967
Load default data. Delete all other existing
942 903
programming, then reloads default data
942 904
Clear all Search Tables (801-815, 821-830,
841-845)
942 906
Enter Clone Master Mode
942 968
Block Initialisation: 0 = Off, 1 = On
942 969
Reset the peg counter
907
Return to data programming mode from data
confirmation mode
999
Exit programming mode
General Notes on Programming
Definition
Fax Business Controller - 17