Mitel SMarT-1 FBC Installation & Programming Manual page 12

Fax business controller
Table of Contents

Advertisement

Hardware Installation
Hardware Specifications
Ordering Information
12 - Fax Business Controller
Ringer Impedance
Ringing Sensitivity (25 Hz):
Off-hook Current
Battery Feed
Open Circuit
Constant Current
Short Circuit Current
MF4 Receiver
Level
Twist
Time between tones
Rotary Receiver (Rate)
MF4 Sender
Levels
dBV(ZR)
Twist
Duration (programmable)
Rotary Sender
Modem (internal)
AC Operating Range
AC Line
Temperature
Humidity
Holdover
Jacks
DC Power
Equipment
Mechanical
Weight:
Dimensions:
Mounting
Regulatory Conformity
Safety
Emissions
Immunity
Network
Italy
Fax Business Controller
Other Components
Italy Power Supply
Italy FBC Exchange Line Spare Cables:
RJ11 plug to RJ11 plug
Important Product and Safety Information
15k min
25 VAC min
17.5 mA min, 125 mA max
15 VDC nominal
20 mA min, 25 mA max
25 mA max
-22 dBm min, +3 max
composite
-6 min +6 max, composite dB
40 ms min
8 min, 12 max (pps)
VF
= -8 dBm +/- 2 dB
L
VF
= -6 dBm +/- 2 dB
H
+/- 1dB
70 ms min
10 pps, 40/60 ms
V.21 CCITT, 300 baud
230 VAC, +/- 10%, 50 Hz,
50 mA Max
-5º to 45 º C
5 to 95%, non condensing
100 ms typical
2.5 mm
RJ11 to RJ11
RJ11 to RJ11
Main Unit: 910 g
PSU: 295 g
Approx. 141mm x 141mm
x 49mm, 5.6" x 5.6" x 2"
Vertical or Horizontal Surface
EN60950
EN50081-1, Class B
EN50082-1
CEI 103-5
8380-003-FBCMXX
8380-024
8380-036
8380-900-025-NQ
8380-377-115-NQ
Issue 1, January 1997