7.5.
Pneuma c data
WARNING
!
Use clean dry air
Do not use compressed air which contains chemicals, synthe)c oils containing organic solvents, salts or corrosive gases, etc., as
this can cause damage or malfunc)on.
CAUTION
!
Install air filter
Install air filters close to valves at their upstream side. A filtra)on degree of 5 μm or less should be selected.
Install an air dryer, aGer cooler or Drain Catch (water separator) etc.
Air that includes excessive moisture may cause malfunc)on of valves and other pneuma)c equipment. To prevent this, install
an air dryer, aFer-cooler, or water separator, etc.
If excessive carbon dust is generated
Eliminate it by installing mist separators at the upstream side of valves. If excessive carbon dust is generated by the
compressor, it may adhere to the inside of valves and cause malfunc)on.
Control medium:
Dust content Quality class 7:
Water content Quality class 3:
Quality class X:
Oil content
Temperature range
of compressed air:
Pressure range:
Connec ons:
Fig. 5:
Pneuma c controller
The exhaust flow rates for both ports can be controlled separately to control the actuator speed in both energising and de-
energising direc)ons
Pg 22
Air, neutral gases
Quality classes in accordance with DIN ISO 8573-1
(5µm filter recommended)
max. par)cle size 40µm
max. par)cle density 10mg/m³
max. pressure dew point –20°C or min. 10°C below the lowest opera)ng temperature
max. 25mg/m³
-10 ... +50° (non-condensing)
2.0 ... 7 bar (minimum air pressure of system may be higher than minimum pressure to
operate solenoid, as required by product condi)ons, valve or actuator)
6mm "One touch" push-in fiBngs, collets and O-rings are replaceable
F783E / F783E 2.0