Cable Gland With Screw Terminals - Pentair F783E Operating Manual

Control head
Hide thumbs Also See for F783E:
Table of Contents

Advertisement

For installa on in Ex. situa on: refer to special condi ons in Sec on 5 of this manual. Use only Ex. cer fied product

12.5.2. Cable gland with screw terminals

Procedure:
Open the control head (follow the instruc)ons in chapter 8 "Opening and closing the housing" if in doubt)
Prepare the cable by stripping back the insula)on to expose approximately 120mm of the cores. Strip each core to expose
8 to 10mm of bare copper.
Insert the cable through the cable gland un)l the outer sheath is able to be secured by )ghtening the gland
Twist each core firmly and fold in half before fiBng to the terminals of the 6-way header plug, the correct loca)on for
each core is printed on the rear of the module, as below in Fig 17.
Tighten the terminal screws
Close the housing (follow the instruc)ons in chapter 8 "Opening and closing the housing" if in doubt)
Fig 17: Electrical connec on AS-interface cable gland
Pg 38
F783E / F783E 2.0
00-ISN-191_Rev C
20/01/2018