For installa on in Ex. situa on: refer to special condi ons in Sec on 5 of this manual. Use only Ex. cer fied product
12.5.2. Cable gland with screw terminals
Procedure:
Open the control head (follow the instruc)ons in chapter 8 "Opening and closing the housing" if in doubt)
⇒
Prepare the cable by stripping back the insula)on to expose approximately 120mm of the cores. Strip each core to expose
⇒
8 to 10mm of bare copper.
Insert the cable through the cable gland un)l the outer sheath is able to be secured by )ghtening the gland
⇒
Twist each core firmly and fold in half before fiBng to the terminals of the 6-way header plug, the correct loca)on for
⇒
each core is printed on the rear of the module, as below in Fig 17.
Tighten the terminal screws
⇒
Close the housing (follow the instruc)ons in chapter 8 "Opening and closing the housing" if in doubt)
⇒
Fig 17: Electrical connec on AS-interface cable gland
Pg 38
F783E / F783E 2.0
00-ISN-191_Rev C
20/01/2018