Summary of Contents for Pentair FLECK 3200 NXT

  • Page 4 CONTINUED WARNING:...
  • Page 6 Flow Split Between Standby Two Meters In Service (Primary Tank) Standby Full Capacity 3/4 Capacity 1/2 Capacity 1/4 Capacity 4th in Standby 3rd in Standby 2nd in Standby 1st in Standby (Primary Valve) System Operation in Regeneration: In Service First Trip Point (Primary Valve) Standby Total Flow Split...
  • Page 7 Steady Flow: In Service In Service Standby Standby Volume Volume Remaining = 0 Remaining = 0 Flow Stays Steady: Regeneration Standby In Service In Service Flow Increases Past the Trip Point: S R V 0 3 : 4 5 P M R E G E N D A Y S Regeneration...
  • Page 9 NOTE: This s een will not display fo System Type CAUTION Example: S Y S T E M S I Z E : alves in t e System (Default) V A L V E S Options: alves in t e System (Default) alves in t e System 4 alves in t e System Range:...
  • Page 10 spa e to t e le t. CONTINUED T R I P D E L A Y S E C O N D S NOTE: Display will not appear unless timer is programmed as valve position #1. System size must be 3 or to appear.
  • Page 11 it will display for all units. CONTINUED E ample: M A X I M U M F L O W Ma im m F o Rate of 0 R A T E : 0 0 0 0 g p m ange: 20 2 000 m (U.S.
  • Page 12 E am le: C U R R E N T F L O W R A T E : g p m Flow rate at this time. E am le: P E A K F L O W R A T E : Peak flow since last regeneration.
  • Page 14 14 17 28 29 37 35 61501-3200NXT-2_Page2_REVA...
  • Page 15 CONTINUED...
  • Page 16 32 52 10 8 27 26 11 61501-3200NXT-3_Pg2_REVA...
  • Page 17 CONTINUED...
  • Page 19 CONTINUED...
  • Page 24 OPTIONAL MOTOR PUMP ON DURING REGENERATION OR CPO DEVICE ON DURING SERVICE (N.O. OUTPUT) SWITCHED HOT NEUTRAL 24VAC 3A MA . RESISTIVE 3 VDC 3A MA . RESISTIVE UNSWITCHED HOT OPTIONAL INTERLOC SWITCH (N.O.) ONL AVAILABLE ON 32 N T AND 3214N T OPTIONAL REMOTE -CLOSED CONTACT PREVENTS REGENERATION SIGNAL START...
  • Page 25 OPTIONAL MOTOR PUMP ON DURING REGENERATION OR CPO DEVICE ON DURING SERVICE(N.O.OUTPUT) SWITCHED HOT NEUTRAL 24VAC 3A MA . RESISTIVE 3 VDC 3A MA . RESISTIVE UNSWITCHED HOT OPTIONAL INTERLOC SWITCH (N.O.) ONL AVAILABLE ON 32 N T AND 3214N T -CLOSED CONTACT PREVENTS REGENERATION OPTIONAL REMOTE -INPUT SIDE PULLED UP TO 32 VDC...
  • Page 26 WHITE/BLACK STRIPE RED/BLACK STRIPE BLUE/WHITE STRIPE BLUE/BLACK STRIPE GREEN/YELLOW WHITE GREEN/BLACK STRIPE 4V AC BELDEN 9458 OR EQUIVALENT METER UPPER DRIVE BLUE ORANGE ORANGE/BLACK STRIPE 31.8 BLACK 1.25 M IN BLACK/WHITE STRIPE RED/WHITE STRIPE GREEN/WHITE STRIPE GREEN BACKPLATE GROUND SCREW CABLE ENTRY SEAL AMP P/N 54 CONNECTOR PLUG...
  • Page 27 TB1 GREY WHITE NEUTRAL WHITE LINE GREEN EARTH GND NOT USED BLUE BLACK TYPICAL OUTPUT WIRING GREY NOT USED TB1 GREY LD SWITCH PINK NEUTRAL LINE NOT USED EARTH GND #RED +5 VDC TB ORANGE #RED/BLACK DC GROUND P/N 19781 BLACK NEUTRAL #WHITE...
  • Page 28 TB1 GREY WHITE WHITE NEUTRAL WHITE LINE GREEN EARTH GND NOT USED BLUE BLACK GREY NOT USED BLACK LD SWITCH PINK NOT USED #RED +5 VDC TB ORANGE #RED/BLACK DC GROUND P/N 19781 BLACK GREEN #WHITE WHITE STEP #BLUE LOCKOUT #WHITE/BLACK HOME #GREEN...
  • Page 29 TB1-GREY WHITE WHITE NEUTRAL WHITE LINE GREEN EARTH GND NOT USED BLUE BLACK GREY NOT USED BLACK PINK LD SWITCH NOT USED TB2-ORANGE RED BLACK DC GROUND P N 19 BLACK GREEN WHITE WHITE STEP BLUE LOCKOUT WHITE BLACK HOME GREEN SENSOR ORANGE...
  • Page 30 TB1-GREY WHITE NEUTRAL WHITE LINE GREEN EARTH GND NOT USED BLUE BLACK GREY NOT USED PINK NOT USED NOT USED TB2-ORANGE RED BLACK DC GROUND P N 197 1 BLACK WHITE STEP WHITE BLUE LOCKOUT WHITE BLACK HOME GREEN SENSOR ORANGE METER BLACK...
  • Page 31 WARNING:...

Table of Contents