Flashing The Firmware Using Afu - Adaptec RAID 21610SA Installation And User Manual

Adaptec serial ata raid
Hide thumbs Also See for RAID 21610SA:
Table of Contents

Advertisement

The AFU switches are as follows
/C <Controller ID> is one or more controller IDs representing
I
the set of controllers on which to perform the specified
command. You can specify a single controller ID, for example:
/C 0
multiple IDs separated by commas, for example:
/C 0,2
or ALL to indicate all controllers.
This switch is required. If no /C switch is specified, the system
returns a fatal error message. See each individual command for
the default switch values.
<UFI File Path> specifies the path (drive and directory)
I
/D
where the UFI files are located. If you do not specify the
switch, the AFU looks for, or creates, its UFI files in the default
location.
Note: You cannot specify the name of a UFI file, only its path.
UFI filenames are predefined, based on the controller type.

Flashing the Firmware Using AFU

The simplest way to flash the controller is to use the AFU GUI.
Follow the instructions in
page B-4
to start AFU with the GUI.
To flash the firmware using the AFU utility from the command
line:
1 Shut down your computer.
2 Insert the bootable disk that contains the AFU utility.
3 Turn on the computer.
4 Enter the system setup utility and verify that your computer is
set up to boot from the bootable disk.
Accessing the AFU from the GUI on
DOS Utilities
/D
B-5