Command Statistics; Device I/O Statistics - Adaptec SCSI RAID 2010S Software User's Manual

Storage management raid controllers
Hide thumbs Also See for SCSI RAID 2010S:
Table of Contents

Advertisement

Command Statistics

Total
Commands
Misaligned
Transfers
SCSI Bus
Resets

Device I/O Statistics

The total number of sectors written to disk by the controller is
described by the formula:
Write – Backs + Write – Throughs = Total Sectors
However, in RAID 1 arrays
Write – Backs + Write – Throughs = 2 ∗ Total Sectors
This is because each sector written from the host results in a write
to each mirrored disk. In a RAID 5, each write from the host can
generate up to two disk reads and two disk writes. Because the
controller has cache memory, the reported number of sectors read
from or written to disk may be less than this value.
The total number of commands received from the
host computer. This includes Read and Write
commands and other commands that may not
involve device I/O.
The number of commands that required data to be
transferred starting at a RAM address location that
was not an even byte value.
The total number of SCSI bus resets that have been
issued by the controller. A large number of resets
can indicate a problem with the SCSI bus or an
attached device.
Storage Manager
3-47

Advertisement

Table of Contents
loading

This manual is also suitable for:

Scsi raid 2015sAsr-2015s

Table of Contents