Replacing A Power Supply Unit - Adaptec DuraStor 6200SR Installation And User Manual

Raid appliance, storage enclosure and storage subsystem
Hide thumbs Also See for DuraStor 6200SR:
Table of Contents

Advertisement

4 Tighten the thumb screws on the cooling fan module. (Do not
overtighten.)
The Fault LED on the front bezel goes out.

Replacing a Power Supply Unit

When a PSU fails
The alarm sounds.
I
The Fault LED on the front bezel lights up.
I
The system monitor displays an error event.
I
A failed PSU should be replaced as quickly as possible to maintain
power system redundancy.
Note: PSUs are hot-swappable.
1 Remove the front bezel. See
2 Turn off the affected PSU.
3 Squeeze the PSU's release latch.
4 Pull the power supply from the RAID appliance. See
Figure 5-4. Removing the PSU
5 Slide the new PSU into the empty bay until it seats completely
and the release latch resets.
6 Turn on the replacement PSU.
7 Replace the front bezel. See
The Fault LED on the front bezel goes out.
Maintaining the DuraStor Storage Subsystem
Removing the Front Bezel on page
Replacing the Front Bezel on page
3-3.
Figure
5-4.
3-6.
5-5