Saf-Te Controller Card - Adaptec DuraStor 6200SR Installation And User Manual

Raid appliance, storage enclosure and storage subsystem
Hide thumbs Also See for DuraStor 6200SR:
Table of Contents

Advertisement

DuraStor 6220SS/6200SR/312R Installation and User's Guide
so that when a data cable is plugged in, the system automatically
senses the connection's ground and provides the required SCSI
termination. No external termination is required.
When you add a jumper to JP2, you disable automatic termination.
In this configuration, the daisy-chained RAID appliance or the host
connection to Channel 2 provides the termination.

SAF-TE Controller Card

The SAF-TE controller card of the DuraStor 312R (see
is installed into the back of the storage enclosure, just above the
disk I/O card. It contains the SAF-TE switches and an RS-232 serial
communications port.
Figure 2-17. DuraStor 312R SAF-TE Controller Card
Warning: The SAF-TE controller card is not hot-swappable.
You must turn the power off to the DuraStor 312R storage
enclosure to replace this card. (See
page
3-23.)
The SAF-TE controller card monitors the disk drives, PSUs, cooling
fans, and enclosure temperature, and continually reports
conditions to the host system. It also sets the drive ID (drive
configuration), the SCSI bus mode, and the disk drive start/spin-
up options.
2-16
R
D
M
S
L
S
2
S
1
A
0
A
1
D
0
B
Drive Address Configurations
and Drive Start/Spin-up
Switches
RS-232 Serial Communications Port
Powering Off on
Figure
2-17)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Durastor 6220ssDurastor 312r

Table of Contents