Xilinx KCU1250 User Manual page 67

Hide thumbs Also See for KCU1250:
Table of Contents

Advertisement

This option returns to the menu level above.
PMBus Menu
The PMBus bus commands are used to read the voltage settings of the KCU1250 board
power rails controlled by the Maxim power system. Through the PMBus menu these power
rails can be read once or scanned continuously until stopped by a key press.
the voltage rails accessible through the system controller's interface to the Maxim PMBus.
Table D-1: Voltage Rails Accessible Through System Controller's Interface to PMBus
Maxim Power Supply Rail
VCCINT
VCCAUX
VCCBRAM
VCCO_HP
VCCO_HR
UTIL_5V0
UTIL_3V3
UTIL_2V5
KCU1250 User Guide
UG1057 (v1.0) December 19, 2014
I2C Address
0x0A
0x0B
0x0F
0x13
0x11
0x1C
0x1D
0x1A
www.xilinx.com
Appendix D: System Controller
Table D-1
Nominal Voltage
0.95V
1.80V
0.95V
1.80V
1.80V
5.00V
3.30V
2.50V
Send Feedback