DV50 DV80
(Integral CO
Sensor)
2
VIEWING THE AWAY PROFILE INFORMATION
If you want to view the Away profile settings, proceed as follows:
1.
Open the Away profile main view.
2.
Press the Profile information button.
3.
The first information screen for the profile appears.
This screen contains the following information:
•
Supply air — Indicates the temperature of the air blown in to
the property and its set value shown in brackets, if the supply
air is warmer than the set value.
•
Outdoor air — Indicates the outdoor air temperature.
•
Fan speed — Indicates the fan speed. If the automatic fan
speed boost is turned on, the set value is shown in brackets
first followed by the actual fan speed.
•
Cell status — Indicates the status of the ventilation unit heat
recovery cell. Possible statuses are:
• Heat recovery — The heat recovery cell heats the air
streaming in from outdoors.
• Cooling — The heat recovery cell cools the air streaming
in from outdoors.
• Cell bypass — The inflowing air by-passes the heat
recovery cell.
• Defrosting — The heat recovery cell is being defrosted.
4.
Press the Right arrow button.
5.
The second information display for the profile opens.
This screen contains the following information:
•
Humidity — Indicates the highest relative humidity of air
measured by the extract air sensor.
•
Carbon dioxide — Indicates the highest carbon dioxide level
measured by the extract air sensor.
•
Change filters — Indicates the next recommended filter
change date.
•
Days in use — Indicates how long the unit has been running
in days and years..
VENTILATION PROFILES
20