Airflow Ceiling fans Owner's Manual

Builder’s choice gallery edition

Advertisement

INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
MOUNTING RECOMMENDATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
GETTING STARTED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
FAN INSTALLATION (USA) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
LIGHT FIXTURE INSTALLATION (USA) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
CONTROL FEATURES: 3-SPEED OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
AUTHORIZED SERVICE CENTERS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
PRODUCT SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Safety and the proper operation of your Airflow fan both require a thorough knowledge of the product and
proper installation; therefore, before attempting to install and operate your Airflow fan, read this owner's
manual completely and carefully. Retain this manual for future reference.
CAUTION: To avoid possible electrical shock, make certain that electricity is turned off at
the circuit breaker or fuse box before attempting any installation procedure.
• All wiring must be in accordance with the National Electric Code ANSI/NFPA 70-1993 and the appropriate local electrical
codes. The National Electric Code requires proper grounding as a precaution against electrical shock. A qualified electri-
cian should be consulted if you are unsure.
• This fan is designed to be installed on an existing electrical outlet box. The outlet box must be UL Listed for ceiling fan
installations, if it is not, a new box must be installed. Airflow extension poles are available for sloped or high ceiling
installations.
• This ceiling fan requires a grounded electrical supply of 120 VAC, 60 Hz and a minimum 15 amp circuit. The maximum
current requirement for the fan with light fixture is 3.8 amps. The fan uses about 1 amp or 100 watts. Maximum light
current is 2.8 amps or 340 watts of lighting.
• Where wire nuts are employed, be sure all bare wires are within the connectors. When installing the canopy hatch, make
sure all wires are within the canopy and that no wires are being pinched.
• The blades in each pack are matched for equal
weight to assure smooth fan operation. If
more than one fan is being installed, be
careful not to mix blades from different
cartons.
• Inspect the contents of your carton for
possible shipping or handling damage and
report any such damage directly to your
authorized Airflow dealer.
• It is always a good idea to have an assistant
to help with the installation.
• When cleaning, painting, or working near
your fan, be very careful of the fan and blades.
Always turn the power OFF to the ceiling fan
before servicing it, working on it, or replacing
light bulbs.
• Never insert anything into the path of the
fan blades while the fan is in operation.
• Never install a fan over a pool or spa.
• Never operate a fan that has been damaged
in any way. Contact Airflow by calling toll-
free 1-888-227-2178, or contact your local
authorized Airflow dealer for assistance in
obtaining service.
CONTENTS
READ AND SAVE THESE INSTRUCTIONS

SAFETY FIRST

BEFORE YOU START

For best performance and for your warranty to be valid,
use only genuine Airflow blades, light fixtures, and accessories.

SAFE USE

(REMOVE FUSE FOR THE
CIRCUIT YOU WILL BE
(TRIP BREAKER FOR THE
CIRCUIT YOU WILL BE
P/N 8943500
FUSE BOX
WORKING ON)
CIRCUIT BREAKER
WORKING ON)
AA0905
B
'
UILDER
G
ALLERY
18"
70"
84"
C
S
HOICE
E
DITION
1

Advertisement

Table of Contents
loading

Summary of Contents for Airflow Ceiling fans

  • Page 1: Table Of Contents

    • This fan is designed to be installed on an existing electrical outlet box. The outlet box must be UL Listed for ceiling fan installations, if it is not, a new box must be installed. Airflow extension poles are available for sloped or high ceiling installations.
  • Page 2: Mounting Recommendations

    Location Ceiling fans have practical uses in almost every room in your home. We suggest you follow these mounting recommendations as you decide where to install your Airflow fan. • For safety reasons, the fan blades must be a minimum of 7' above the floor.
  • Page 3: Getting Started

    Before discarding packaging material, be certain that all parts have been removed. Be sure to only use genuine Airflow blades. The blade shrink CAUTION: When removing the shrink wrap, wrap holds five blades of matched weight. If more than one be careful not to scratch the blades.
  • Page 4: Mounting Bracket Installation

    CEILING FIXTURE OUTLET BOX Installing a New Ceiling Fixture Outlet Box Using Existing Ceiling Fixture Outlet Box If you do not have an existing fixture located where you wish After turning the power OFF at its source (either circuit breaker to place your fan, an approved ceiling fixture outlet box must or fuse box), lower the old fixture and disconnect the wiring.
  • Page 5: Electrical Connections

    ’ UILDER HOICE ™ ALLERY DITION ELECTRICAL CONNECTIONS WIRE NUT BLUE Step 9. Attach the fan wires to the ceiling fixture D1-OPTION outlet box wiring by twisting the bare ends of the WIRE wires together and then securing with a wire nut. Test that the connection is secure by pulling on the wire nut.
  • Page 6: Remove Shipping Blocks

    REMOVE SHIPPING BLOCKS Step 13. On the motor remove the five shipping blocks by unscrewing the screws. Set these screws aside for installing the blades in Step 14. Discard the five shipping blocks. Note: Save these five screws, they will be used in Step 14! SHIPPING BLOCKS BLADE &...
  • Page 7: Light Fixture Installation (Usa)

    ’ UILDER HOICE ™ ALLERY DITION LIGHT FIXTURE INSTALLATION Step 15. Remove light kit fitter from carton. Using a Phillips screwdriver, unscrew the three screws from the fan and set aside. Connect the 9-pin connector from the fan to the connector on the light kit fit- ter as shown, aligning the red squares and making sure they snap into place.
  • Page 8: Control Features: 3-Speed Operation

    Let fan run at high speed for two hours. DOES NOT RUN ON If new, “break-in” may be required. Run at higher speed for several days. LOW SPEED For questions or to locate the nearest Airflow Authorized Service Center, call toll free: 1-888-227-2178...
  • Page 9: Authorized Service Centers

    AUTHORIZED SERVICE CENTERS STATE/CITY SERVICE CENTER NAME PHONE TYPE STATE/CITY SERVICE CENTER NAME PHONE TYPE ALABAMA LOVELAND 80538 FIRESIDE LIGHTING INC. 970-669-3540 OWTS COLORADO SPRINGS 80903 HOME LIGHTING INC. 719-471-3520 OWTS MOBILE 36618 AZALEA CITY SERVICE CENTER 251-341-0663 TUSCALOOSA 35405 LTG.
  • Page 10 STATE/CITY SERVICE CENTER NAME PHONE TYPE STATE/CITY SERVICE CENTER NAME PHONE TYPE MONTICELLO 52310 REM ELECTRIC INC. 319-465-3346 MISSOULA 59801 WESTERN MONTANA LTG SPY 406-543-7166 DES MOINES 50311 ADVANCED LIGHTING 515-255-5009 OWTS IOWA (CONTINUED) NEBRASKA CARROLL 51401 J & L ELECTRIC INC. 712-792-2444 OMAHA 68104...
  • Page 11: Product Specifications

    CARROLLTON 75006 ADFANTAGE CEILING FAN 972-446-9393 HUMBLE 77338 CAROLS LTG. & FAN SHOP 281-446-7613 OKLAHOMA AUSTIN 78703 TEXAS CEILING FANS/CEILING FAN SHOP 512-477-3132 OKLAHOMA CITY 73105 APPLIANCE SERVICE BY CK 405-525-8862 HOUSTON 77069 CHAMPIONS LIGHTING 281-440-5339 OKLAHOMA CITY 73132 LARKIN E. STEVENSON...

This manual is also suitable for:

200g-xx