FIREPLACE PROFILE
When you want to set the Fireplace function settings, proceed as
follows:
1. The deployment wizard Fireplace function profile screen is
opened.
2. Set the profile timer duration in minutes by using the Plus and
Minus buttons.
3. The profile duration is now set.
4. Press the Right arrow button.
5. The screen for setting the profile supply air fan speed appears.
6. Set the Fireplace function supply air fan speed as a
percentage of the maximum by using the Plus and Minus
buttons.
TIP
In the fireplace mode, we recommend that you increase the
supply air fan speed, in order to obtain a positive pressure at the
ventilation zone. We do not recommend reducing the extract air fan
speed.
7. The Fireplace function supply air fan speed is now set.
8. Press the Right arrow button.
9. The screen for setting the profile extract air fan speed appears.
10. Set the Fireplace function extract air fan speed as a
percentage of the maximum by using the Plus and Minus
buttons.
11. The Fireplace function extract air fan speed is now set.
12. Press the Right arrow button.
13. The profile timer setting screen is displayed.
14. Use the Plus and Minus buttons to select whether the profile
timer function is enabled or not. The options are:
• On — When the timer is enabled, the Fireplace function
is only on for the period defined in the timer.
• Off — When the timer is disabled, the Fireplace function
is used until you (or the week clock) change the profile.
15. The profile timer function is now set.
16. Press the OK button.
17. The Fireplace function settings are now complete.
16