SETTINGS
MODIFYING THE AWAY PROFILE SETTINGS
1.
Open the Away profile main view.
2.
Press the Profile information button.
3.
Press the Edit button.
4.
The fan speed setup opens.
5.
Set the Away profile fan speed as a percentage of the
maximum by using the Plus and Minus buttons.
6.
Press the Right arrow button.
7.
The temperature setup screen is opened.
8.
Set the desired supply air temperature for the Away profile
by using the Plus and Minus buttons. You can adjust the
temperature in the range +10°C ... +5°C. The recommended
temperature is +15°C or 2—3°C below the room temperature.
9.
Press the Right arrow button.
10. The setup screen for automatic fan speed control, based on
the relative humidity, appears.
11. Use the Plus and Minus buttons to select whether the
automatic fan speed control, based on the relative humidity, is
used or not.
12. Press the Right arrow button.
13. The setup for automatic fan speed control based on the
carbon dioxide or VOC level opens.
14. Use the Plus and Minus buttons to select whether the
automatic fan speed control, based on the carbon dioxide or
VOC level, is used or not.
15. Press the OK button.
(Integral CO
23
© Airflow • We reserve the right to make changes without prior notice
DV50 DV80
Sensor)
2