Rebuilding A Failed Array; Formatting A Drive - Scsi Only - Adaptec 750i User Manual

Storage management software
Hide thumbs Also See for 750i:
Table of Contents

Advertisement

Rebuilding a Failed Array

To replace a failed drive in an array that is not protected by an
automatic hot spare, follow these steps:
1
Remove and replace the failed drive according the procedures
in your hardware documentation.
2
When the failed drive has been replaced, select
RAID > Rebuild Array to start the rebuild process.
The status of the array changes to Rebuilding (view the Information
tab for that array). When the rebuild is complete, the array status
changes to Optimal.
Note: An Adaptec RAIDstation enclosure automatically
detects the replacement of a failed drive and initiates a
rebuild operation as soon as the new drive is online.
Formatting a Drive – SCSI only
Formatting hard drives is not normally required. However, if you
have a drive that was previously formatted with a sector size other
than 512 bytes, low-level format the drive to 512 bytes/sector.
Caution: Do not remove power from the drive until the
!
format operation is completed. Doing so may damage the
drive so that it requires factory repair or replacement.
Low-level formatting large capacity drives can take considerable
time. To perform a low-level format on a hard drive, follow these
step:
1
Highlight the drive to be formatted
2
Select Action > Format Drive.
3
Select Ok and confirm. To determine if the format has
completed, view the Information tab for that drive.
Storage Manager on ROM
2-31

Advertisement