Adaptec 750i User Manual page 60

Storage management software
Hide thumbs Also See for 750i:
Table of Contents

Advertisement

Name
Configure
Print
Build
Rebuild
Stop Bld
Stop Vfy
Creating an Array Group
To create an array group, follow these steps:
1
Select the Create Array Group button. The Select Array Type
window appears, as shown in
2
Select the desired Fault Tolerance: Drive fault tolerance
(RAID 1 or 5) or No fault tolerance (RAID 0).
3
Select the desired Optimization: Optimize for Capacity
(RAID 5) or Optimize for Performance (RAID 1).
Allows entering or changing the name to be shown
for this RAID array. This does not affect the LSU of
the array. For more information, see
Allows changing the configuration of the array.
Prints the configuration file of the selected RAID
array.
Arrays that have a build pending display this
button.
Redundant arrays that have a failed drive show this
button.
Arrays that are building or rebuilding show a Stop
Bld button.
Arrays running a Verify operation show this button.
Figure 3-10. Select Array Type Window
Figure
3-10.
Storage Manager
page
3-23.
3-16

Advertisement