Hot-swap drive replacement

Follow these instructions to replace a front SSD in the ThinkAgile CP compute block appliance.
Each ThinkAgile CP compute block appliance supports Intel 240GB solid-state drives (SSDs). These drives
are used for installing the operating system and no user data are stored on these drives. These drives are
used in RAID 1 mode.
Always replace failed data drives as soon as possible. The following indicate a failed front SSD:
• On cloud controller or portal
• The yellow status LED on the node front panel is illuminated.
Remove a hot-swap drive
Use this procedure to remove a drive.
Chapter 3 "Read
the
Installation
Guidelines" on
page 19
Before you remove a drive, ensure that you save the data on your drive (especially if it is part of a RAID array)
before you remove it from the node.
Procedure performed by: customer or field service
Attention:
• To ensure that there is adequate system cooling, do not operate the solution for more than 2 minutes
without either a drive or a filler panel installed in each bay.
• Before you make changes to drives, drive controllers (including controllers integrated on the system
board), drive backplanes, or drive cables, back up all important data stored on drives.
• Before you remove any RAID array components, back up all RAID configuration information.
• If one or more NVMe solid-state drives are to be removed, disable them in OS before removal.