Lenovo ThinkAgile CP Hardware Part Replacement And Component Maintenance Procedures page 125

Table of Contents

Advertisement

The installation of the DIMM is now complete.
After you install a DIMM, complete the following steps:
1. Reinstall the air baffle (see
2. Reinstall the compute node cover (see
compute_node_cover.html
3. Reinstall the compute node (see
node_in_the_chassis.html
4. Check the power LED to make sure it transitions between fast blink and slow blink to indicate the node
is ready to be powered on.
5. Power on the node.
6. Exit maintenance mode.
7. Verify that the DIMM memory failure is resolved by reloading the system. If successful, no POST errors
appear during the booting process.
8. If you are instructed to return the component or optional device, follow all packaging instructions, and
use any packaging materials for shipping that are supplied to you.
http://thinksystem.lenovofiles.com/help/topic/7X21/install_the_air_baffle.html