EIOM replacement

Use the following procedures to remove and install the Ethernet I/O module (EIOM).
The ThinkAgile CP Compute Block appliances offer connectivity to the LOM (LAN on motherboard) of each
node via ports on the EIOM located at the rear of the enclosure. The top Phy maps to port one of the system
LOM, the bottom Phy maps to port two of the system LOM.
The ports are labeled sequentially from left to right.
Figure 50. EIOM ports and corresponding node number
Table 4. EIOM port corresponding node number
1
Ports to node 1
2
Ports to node 2
3
Ports to node 3
4
Ports to node 4
Remove the EIOM
Use this information to remove the EIOM.
Chapter 3 "Read
the
Installation
Guidelines" on
page 19
Before you remove the EIOM:
1. Place the node in maintenance mode.
2. Power off all compute nodes and peripheral devices.
3. Disengage all the compute nodes from the enclosure (see
7X21/remove_a_compute_node_from_the_chassis.html
4. Disconnect the power cords and all external cables from the rear of the enclosure.
5. If the cable management arm is installed, remove it (see
7X21/remove_the_cable_management_arm.html
6. Remove the shuttle (see
place it on a stable work surface.
"Power off
the compute
node" on page
).
http://thinksystem.lenovofiles.com/help/topic/7X21/remove_the_shuttle.html
119
http://thinksystem.lenovofiles.com/help/topic/
).
http://thinksystem.lenovofiles.com/help/topic/
.
Chapter 5
Part replacement and maintenance procedures
"ATTENTION:
Static Sensitive Device
Ground package before
opening" on page 21
) and