Remove an interconnect switch
Procedure for removing the Lenovo ThinkAgile CP interconnect.
Procedure performed by: customer or field service
To remove the ThinkAgile CP interconnect from a standard rack, complete the following steps:
Step 1.
Disconnect all external cables on power and Ethernet ports.
Step 2.
Loosen and remove the screws (1) and clip nuts (or cage nuts) to release the switch and the rail
from the rack.
Step 3.
Remove the switch from the rail.
Step 4.
Remove the two screws (2) used to secure each of the rear-post brackets at the midpoint on the
sides of the rails.
Step 5.
Remove the four screws (3) on the front- and rear-post brackets.
Figure 58. Removing the interconnect from the rack
Replace the interconnect switch by following the steps in "Install the ThinkAgile CP interconnect switch" on
page 128.
.
Chapter 5
Part replacement and maintenance procedures
127