RADION receiver SD
During this test mode, motion detected within the detector's
coverage area causes a transmitted alarm and LED activation.
Each alarm will also extend the Test Mode. Watch for the green
LED to indicate the edges of the Microwave pattern. Adjust as
necessary.
Please reference the LED table below for LED descriptions.
LED Condition
Steady LED
Steady green
Steady blue
Flashing blue
No LED upon initial
power up
Tab. 6.9: LED description
Walking Testing the system
1.
2.
Bosch Security Systems B.V.
Start at the pattern's expected boundary and walk across
the pattern moving closer to the detector. Set the
adjustment as low as possible for proper catch
performance.
Adjust the Microwave Range Adjustment Potentiometer to
as low a setting as possible for proper catch performance.
Cause
PIR activation (Walk Test)
Microwave activation
Alarm signal
Warm-up period after power-up
PIR failure. Replace unit.
RADION TriTech | en
2020.05 | 13 | F.01U.261.834