Table A-3 Environmental Limits - Sun Microsystems Ultra 1 140 Service Manual

Hide thumbs Also See for Ultra 1 140:
Table of Contents

Advertisement

A
A.2 Electrical Specifications
A.3 Environmental Requirements
Temperature
Humidity
Altitude
Max Dwells at Extremes
A-2
Table A-2 AC/DC Power Supply Specifications
Parameter
Description
Input
Voltage range
Current, maximum
Current frequency range
Output
1
2
3
4
5
Input Power rating
Volt-Ampere rating
Power factor

Table A-3 Environmental Limits

Operating
Operating
U.S.A
Metric
41 - 104 °F
5-40 °C
20 - 80 %
20 - 80 %
Noncondensing
Noncondensing
@ 104 °F
@ 40 °C
70.1 KPa
3 Km
16 hours
16 hours
Sun Ultra 1 Series Service Manual—November 1995
Value
100 to 240 VAC
3.1 to 1.5A
47 to 63 Hz
+5V, 18A
+3.3V, 12 A
+2.5 to 3.6 V, 12 to 8.3 A
+12V, 5.1 A
-12V, 0.3 A
260 W
260 VA
>.98
Non-operating
Non-operating
U.S.A
Metric
-40 - 140 °F
-40 to 60 °C
95 %
95 %
Noncondensing
Noncondensing
@ 104 °F
@ 40 °C
19.2 KPa
12 Km
16 hours
16 hours

Advertisement