[A]: This white lever should move from the front to the center when closed. This indicates that the rollers are
loaded up with the proper tension.
Symptom
1121/1012/1011 Jam Codes resolved with adjusting the Curl Correction for each drawer (Staple/Booklet

Finisher-A1)

Description
Intermittent jam codes 1121, 1012 and 1011 were observed after installing the machine.
- 1121: Stationary jam at Inlet sensor (S101)
- 1012: Delay jam at Feed path senor(S102)
- 1011: Delay jam at Inlet sensor (S101)
Field Remedy
In this case, adjusting the Curl Correction for each drawer resolved the jam codes.
Press (Settings/Registration) > "Adjustment/Maintenance" > "Adjust Action" > "Correct Curl for Each Paper
Drawer".
This mode enables you to adjust the curl correction level of each paper source.