A) Procedure for replacing the fixing drawer connector terminals (fixing drawer cables) on the fixing
assembly side
1) Remove the screw [2] fixing the white high-voltage cable [1] on the fixing base assembly to free the white
high-voltage cable from the front side of the fixing frame.
2) Remove the 2 wire saddles [1] and the gray cables [2], and then remove the white high-voltage cable [3].
3) Remove the screw [2] fixing the fixing inlet guide [1], and then remove the fixing inlet guide from the fixing
base assembly.