ML20600 Series Mortise Lock
Product
1-Black
Corbin Russwin
12/24VDC
Access 600
(Reader)
Mortise
NEG
Cylindrical/Exits
NEG
*Diagram on following page
If your lock is configured with End of Line Resistors, reference instruction sheet FM406 for the wiring
of RX & DPS outputs.
Reader LED Configuration
The Access 600 series reader can be configured for (3) modes of LED
operation. Call 1-800-810-WIRE for details.
Mode 1:
Red LED 'ON' when powered.
• Presenting a valid credential will cause LED to 'FLICKER' green
and return to red state.
Mode 2:
Green LED "ON" when powered.
• (No Flicker) after presenting valid credential.
Note: LED wire must be connected to circuit GROUND of the
system's power supply.
Mode 3:
EAC Panel controls LED operation.
Note: Control of LED is a function of the EAC panel equipment (i.e. relay) to toggle between green and red.
Note: When LED wire is tied directly into EAC panel relay, no AC signals should be applied on wire -
door reader performance will be impacted.
Wire from EAC panel to door must be shielded with drain terminated at EAC panel controller
Total
One-Way
Length of
Wire Run (ft)
1/4A
1/2A
100
20
18
150
18
16
200
16
14
250
16
14
300
16
12
400
14
12
500
14
10
750
12
10
1,000
10
1,500
10
Copyright © 2017 Corbin Russwin, Inc., an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the
express written permission of Corbin Russwin, Inc. is prohibited.

6) Wiring Diagrams

8 PIN CONNECTOR
2-Red
3-White
4-Green
ACCESS CONTROL DEVICES: Harmony H2 Mortise, ElectroLynx wire Color / Function assignments
WIE-
WIE-
GAND
GAND
POS
DATA_1
DATA_0
POS
DATA_1
DATA_0
Load Current @ 12VDC
3/4A
1A
1-1/4A
1-1/2A
2A
16
14
14
12
12
14
12
12
12
10
12
12
10
10
12
10
10
10
12
10
10
10
10
5-Orange
6-Blue
7-Brown
RX
RX
EGND
NO
COM
REF.
*DIA-
GRAMS
NO
COM
Wire Gauge Charts
Total
One-Way
Length of
3A
Wire Run (ft)
1/4A
10
100
24
150
22
200
20
250
18
300
18
400
18
500
16
750
14
1,000
14
1,500
12
5
4 PIN CONNECTOR
8-Yellow
1-Violet
2-Gray
LED
12/24 VDC
(LOCK RELAY)
REF.
NEG
POS
*DIA-
GRAMS
NEG
POS
PIN8 (Yellow – LED)
PIN 6 (Blue – RX COM)
PIN 4 (Green – Data 0)
PIN 2 (Red – Reader POS)
PIN 1 (Black – Reader NEG)
PIN 3 (White – Data 1)
PIN 5 (Orange – RX NO)
PIN 7 (Brown - Earth Ground)
PIN 4 (Tan – DPS COM)
PIN 2 (Gray – Lock POS)
PIN 1 (Violet – Lock NEG)
PIN 3 (Pink – DPS NC)
1/2A
3/4A
1A
1-1/4A
1-1/2A
20
18
18
16
16
18
16
16
14
14
18
16
14
14
12
16
14
14
12
12
16
14
12
12
12
14
12
12
10
10
14
12
10
10
12
10
10
10
10
10
3-Pink
4-Tan
DPS
DPS
(NC)
(COM)
DPS
DPS
-
-
Load Current @ 24VDC
2A
3A
14
12
12
10
12
10
12
10
10

Advertisement

loading