ML20600 Series Mortise Lock
5.
Install Lock Body into Door:
a. Feed wires through 1-5/16" diameter hole on INSIDE of door while installing lock body (Fig. 5a).
b. Pull wires through hole while inserting lockbody. DO NOT push wires back into cylinder hole (Fig. 5b).
Important: Door must remain open during installation. Use door stop.
c. Install, but do not tighten two #12 x 1" combination screws through lock body (Fig. 5a).
Fig. 5a
6.
Install Outside Escutcheon and Inside Mounting Plate
NOTE: Feed mortise connectors through the corresponding hole on the mounting plate.
a. Attach the mounting plate using (2) 8-32 x 2" Phillips flat head
undercut screws in the upper right and middle left positions
of the mounting plate.
Fig. 6a
Copyright © 2017 Corbin Russwin, Inc., an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the
express written permission of Corbin Russwin, Inc. is prohibited.
7) Installation Instructions (Continued)
Outside Face of Door
(2) #8 x 2" Flat Head Srews
10
(2) #12 x 1"
Do not fully
tighten
Fig. 5b
Inside Face of Door
(2) #8-32 x 2"
Flat Head Screws
Reader Wires and
ElectroLynx® Wires
Lock Body Wires
Fig. 6b