ML20600 Series Mortise Lock
11. Install Controller
Once wires are arranged, position controller at a rotated angle against the door,
under earth ground wire.
a. Press piece against door while turning clockwise (Fig. 11a).
b. Twist into place, perpendicular with door (Fig. 11a, b).
c. Position two-wire green/yellow ground wire ring terminal over hole for top
left screw (Fig. 11b, c).
d. Position green/yellow reader harness earth ground on top of two-wire
ground ring and thread both with (1) 8-32 x 3/8" Phillips flat head undercut
combo screw (Fig. 11c).
IMPORTANT: Note orientation of ground ring terminals in Fig. 11B-D.
e. Tighten securely.
Copyright © 2017 Corbin Russwin, Inc., an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the
express written permission of Corbin Russwin, Inc. is prohibited.
7) Installation Instructions (Continued)
Inside Face
of Door
(1) 8-32 x 3/8" Phillips
Flat Head Undercut
Combo Screw
Fig. 11b
13
Fig. 11a
Inside of Door
Fig. 11c
Rotate
Clockwise