ML20600 Series Mortise Lock
Typical ML20600 x M812 Series Lock Application Diagram (12/24VDC Lock)
Standard Application Shown - For Alternative Applications Contact 1-800-810-WIRE (9473)
Reader Electronics Require 12 or 24VDC UL294 Listed, Power Limited Power Supply (or UL603)
12/24VDC System
Reader Draw = 150mA @12 or 24VDC
Actuator Draw = 15mA Continuous (400mA Inrush)
Total System Draw = 550mA
ElectroLynx Harness
From McKinney
NOTE:
If your lock is configured with End of Line Resistors,
reference instruction sheet FM406 for the wiring of
RX & DPS outputs.
Copyright © 2017 Corbin Russwin, Inc., an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the
express written permission of Corbin Russwin, Inc. is prohibited.
6) Wiring Diagrams (Continued)
This product is polarity sensitive; if the lock
does not operate, check the polarity of the
input and reverse if necessary.
12 Conductor
QC12 Electric
Hinge From
McKinney
*IMPORTANT: Pin 7 must be tied to ground in the access control panel.
Failure to follow proper ESD safe grounding procedures could lead to equipment failure.
Lockbody
H
Power Supply
120 VAC
(By Others)
12/24VDC
Input
-
READER NEG - Black, 1
READER POS - Red, 2
DATA 1 - White, 3
DATA 0 - Green, 4
RX (NO) - Orange, 5
RX (COM) - Blue, 6
*EARTH GROUND - Brown, 7
LED - Yellow, 8
Not Used
LOCK NEG - Violet, 9
LOCK POS - Gray, 10
DPS (NC) - Pink, 11
DPS (COM) - Tan, 12
6
Access 600 Reader Electronics
N
G
Require 12 or 24VDC UL294 Listed,
Power Limited Power Supply (or UL603)
+
ULC-S319 compliance:
EAC power supply utilizing battery backup
(30 minutes operation) is required.
Access 600 Series M812
UL294 Listed EAC Panel
Electrical
(-)
12/24VDC
(+)
DATA 1
DATA 0
(By Others)
RX (NC)
Use
RX (COM)
(NC) for
Fail Safe
Operation
Lock Relay
DPS
DPS
(NO) Fail
Secure
Operation
Access
Control
Panel