Download Print this page

Assa Abloy Corbin Russwin Access 600 ML20600 TCRNE1 Series Installation Instructions Manual page 14

M812 - iclass se reader option
Hide thumbs Also See for Corbin Russwin Access 600 ML20600 TCRNE1 Series:

Advertisement

ML20600 Series Mortise Lock
12.
Connector Attachment (Controller)
a. Connect P3 (2-pin connector) from lock body
to J3 on module (Fig. 12).
b. Connect P4 (6-pin connector) from lock body
to J4 on module (Fig. 12).
13.
Inside Eschutcheon Assembly:
a. Tighten the inside escutcheon securely to the
mounting plate with the Phillips flat head
machine screws provided.
Use the 8-32 x 5/8" for the top of the escutcheon
and the 8-32 x 1/4" screws for the bottom of the
escutcheon located under the turn lever.
Remember the inside gasket must be used
when installing in an outdoor application.
b. Be sure the turn assembly is functional and, if
equipped with a deadbolt, that the deadbolt
functions properly.
Copyright © 2017 Corbin Russwin, Inc., an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the
express written permission of Corbin Russwin, Inc. is prohibited.
7) Installation Instructions (Continued)
14
Fig. 12
P3
P4
Inside Face of
Door
8-32 X 5/8" Phillips
Flat Head Undercut
Machine Screw
8-32 X 1/4" Phillips
Flat Head Undercut
Machine Screw
Fig. 13

Advertisement

loading