ML20600 Series Mortise Lock
Mechanical Operational Check
Before closing door, test lock cylinder and inside lever function:
a. Insert key into cylinder and rotate.
b. Check to make sure that the key retracts the latch.
The key should rotate freely.
c. Check to make sure that the inside lever retracts the latch.
d. Close door. Ensure that the latch fully extends into strike and
does not bind.
Electrical Operational Check
Once electrical wiring has been completed follow these steps:
a. Turn power "ON" at EAC panel.
b. Verify reader LED is "ON" (red or green depending on reader con-
figuration. Refer to reader LED configuration).
c. Present proximity credential and verify LED and sounder activity.
d. Verify that a valid card read at EAC Panel.
e. Verify system operation so that when a credential is presented
credential to the reader, the door unlocks.
Wiegand Test Unit
The ASSA ABLOY Wiegand Test Unit verifies your installation in
the field. The test unit checks for proper wiring, card reader data
integrity, lock functionality including lock/unlock, door position
status, and request-to-exit (REX) status.
In addition, this tool provides product demonstration abilities to
highlight the product's features and capabilities.
Copyright © 2017 Corbin Russwin, Inc., an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the
express written permission of Corbin Russwin, Inc. is prohibited.

8) Operational Check

19
Feature
WT1
12 or 24VDC solenoid
X
lock voltage adjustable
Operates as Fail Safe or
X
Fail Secure
"Learn" mode allows
testing of specific cards
X
without programming at
the panel level
Card reader data inte-
grity is validated at test
X
unit
Works with SE LP10
X
Displays detailed
Wiegand data, including
hexadecimal string and
total bits received
Displays measured end-
of-line resistor values
(if applicable)
WT2
X
X
X
X
X
X
X

Advertisement

loading