Figure 15. Configuration mode window
Chapter 3. Configuring two ServeRAID controllers in a failover environment (Windows NT 4.0 and Windows 2000 only)
2. In the Main Tree, click the first ServeRAID controller that you want to
configure.
Important
The ServeRAID controller should be initialized only one time, when the controller is first
installed. Initializing the controller removes all configuration information from NVRAM. This
information includes the SCSI IDs, the Controller host ID and the Cluster partner host ID,
and the array information. This point is especially important if the Windows NT or Windows
2000 system startup drive is attached to the IBM ServeRAID controller. If the initialization
occurs after the startup drive array has been created, the array information will be removed
and the system will no longer start in Windows NT or Windows 2000.
If you already have logical drives defined that you want to keep, go to step 6 on page 64.
The steps before step 6 on page 64 will cause loss of data by deleting all logical drives
already defined.
3. Click Actions → Restore to factory default settings.
4. If a confirmation window opens, click Yes. When the operation is complete, a
message displays at the bottom of the window indicating the restore to factory
default settings was successful.