BCS
ECS
Explanation and possible recovery action
03
88
Explanation:A drive was imported from another system and it has valid configuration, and
Online/Rebuild drives are not responding.
Action:Press F4, F5, F7, or F10.
03
98
Explanation:A drive was imported from another system and it has valid configuration, and
Online/Rebuild and Hot Spare/Standby Hot-Spare drives are not responding.
Action:Press F4, F5, F7, or F10.
03
A8
Explanation:A drive was imported from another system and it has valid configuration, and
Online/Rebuild and Ready/Standby drives are not responding.
Action:Press F4, F5, F7, or F10.
03
B8
Explanation:A drive was imported from another system and it has valid configuration, and
Online/Rebuild, Hot-Spare/Standby Hot-Spare, and Ready/Standby drives are not responding.
Action:Press F4, F5, F7, or F10.
03
C8
Explanation:A drive was imported from another system and it has valid configuration, and
Online/Rebuild drives are not responding and unidentified drives were found.
Action:Press F4, F5, F7, or F10.
03
D8
Explanation:A drive was imported from another system and it has valid configuration, and
Online/Rebuild and Hot-Spare/Standby Hot-Spare drives are not responding and unidentified
drives were found.
Action:Press F4, F5, F7, or F10.
03
E8
Explanation:A drive was imported from another system and it has valid configuration, and
Online/Rebuild and Ready/Standby drives are not responding and unidentified drives were found.
Action:Press F4, F5, F7, or F10.
03
F8
Explanation:A drive was imported from another system and it has valid configuration, and
Online/Rebuild, Hot-Spare/Standby Hot-Spare, and Ready/Standby drives are not responding
and unidentified drives were found.
Action:Press F4, F5, F7, or F10.
07
00
Explanation:The specified drive is not responding:
(Channel: sid) (x : y)
where x is the channel and y is the ID of the drive that is not responding.
Action: Press F4 or F10. When you warm-start the server, if a "Configuration change error"
displays, select F4. Do not select F10. If you do select F10, contact the IBM Personal Computer
HelpCenter.
To correct the problem:
1. Download and install the latest version of IBM ServeRAID software. See "Obtaining
ServeRAID updates" on page 13 for more information.
2. Replace the failed physical drive.
07
08
Explanation:Online/Rebuild drives are not responding.
Action:Press F4, F5, or F10.
07
0C
Explanation:Online/Rebuild drives are not responding, and a drive was found at the incorrect
SCSI ID.
Action:Press F4, F5, F6, or F10.