Operational Check - Assa Abloy Corbin Russwin ED5200N Series Installation Instructions Manual

Exit devices for 9600 tcrne1 series trims m812 - iclass se reader option
Hide thumbs Also See for Corbin Russwin ED5200N Series:
Table of Contents

Advertisement

ED5200N Series Exit Devices
a. Insert key into cylinder and rotate.
b. With key rotated turn lever and check that latch retracts.
c. Check that push bar fully retracts the latch.
d. Close door: Ensure latch fully extends into strike and does not bind.
Note: For fail safe trim, cylinder will have to be tested after wiring is complete and power is turned on.
Once electrical wiring has been successfully
completed according to proper application, perform the following steps:
a. Turn power ON.
b. Verify LED located on reader is ON (Red or Green
depending on reader configuration (See reader LED
Configuration).
c. Present proximity credential and verify LED and
sounder activity.
d. Verify valid card read at EAC Panel.
e. Verify system operation functions; i.e., when prox credential
is presented to reader that the door unlocks.
Wiegand Test Unit
The ASSA ABLOY Wiegand Test Unit verifies your installation in
the field. The test unit checks for proper wiring, card reader data
integrity, lock functionality including lock/unlock, door position
status, and request-to-exit (REX) status.
In addition, this tool provides product demonstration abilities to
highlight the product's features and capabilities.
Copyright © 2018 Corbin Russwin, Inc., an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the
express written permission of Corbin Russwin, Inc. is prohibited.

9) Operational Check

18
Feature
WT1
12 or 24VDC solenoid
X
lock voltage adjustable
Operates as Fail Safe or
X
Fail Secure
"Learn" mode allows
testing of specific cards
X
without programming at
the panel level
Card reader data inte-
grity is validated at test
X
unit
Works with SE LP10
X
Displays detailed
Wiegand data, including
hexadecimal string and
total bits received
Displays measured end-
of-line resistor values
(if applicable)
WT2
X
X
X
X
X
X
X

Advertisement