Assa Abloy Corbin Russwin ED5200N Series Installation Instructions Manual page 13

Exit devices for 9600 tcrne1 series trims m812 - iclass se reader option
Hide thumbs Also See for Corbin Russwin ED5200N Series:
Table of Contents

Advertisement

ED5200N Series Exit Devices
10. Install Controller (for Access 600 x M812)
Once wires are arranged, position controller at a rotated angle against the door,
under earth ground wire.
a. Press piece against door while turning clockwise (Fig. 10a).
b. Twist into place, perpendicular with door (Fig. 10b).
c. Position green/yellow ground wire ring terminal (from lock body)
over hole for top left screw (Fig. 10b, c).
d. Position green/yellow reader harness earth ground on top of
ground ring and thread both with (1) 8-32 x 3/8" Phillips flat head undercut
combo screw (Fig. 10c).
IMPORTANT: Note orientation of ground ring terminals in Fig. 10b, c.
e. Tighten securely.
Fig. 10b
11. Connector Attachment (Exterior PCB Assembly)
a. Connect P3 (2-pin connector) from lock body to J3
on module (Fig. 11).
b. Connect P4 (6-pin connector) from lock body to J4
on module (Fig. 11).
Copyright © 2018 Corbin Russwin, Inc., an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the
express written permission of Corbin Russwin, Inc. is prohibited.
7) Installation Instructions (Continued)
Inside of
Door
(2) 8-32 x 3/8" Phillips
Flat Head Undercut
Combo Screw
13
Fig. 10c
P3
Fig. 11
Rotate Clockwise
Fig. 10a
P4