6.
Install Outside Reader and Inside Mounting Plate:
If this installation involves a surface vertical rod, go to the Surface Vertical Rod sectoin on page 12.
a. Feed Reader wire harness through door and through hole in mounting plate (Fig. 6a).
b. Insert two #8 x 1-3/4" flat head through mounting plate and into escutcheon (Fig. 6a and 6b).
c. Connnect pin 5 green/yellow ground wire ring terminal to top right screw (Fig. 6b and 6c).
Note: Be careful not to pinch wires under mounting plate.
d. Check that Reader is straight on door then tighten screws.
e. Drill two 1/8" diameter holes and install (2) #8 x ¾" combination screws through plate
and into face of door.
Fig. 6a
7.
Install Gasket:
Add Gasket (if necessary):
Remember the inside gasket must be used when installing in an
outdoor application.
Remove backing and place gasket on door (Fig. 7).
Copyright © 2018 Corbin Russwin, Inc., an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the
express written permission of Corbin Russwin, Inc. is prohibited.
7) Installation Instructions (Continued)
11
Fig. 6b
Fig. 7
Fig. 6c Detail
Inside Face of
Door
Gasket required
for exterior door
applications.