ED5200N Series Exit Devices
Typlcal ED5200N M812 Series Lock Application Diagram
Standard Application Shown - For Alternative Applications Contact 1-800-810-WIRE (9473)
Reader Electronics Require 12 or 24VDC UL294 Listed, Power Limited Power Supply (or UL603)
Door Status Switch
12 Conductor
ElectroLynx Harness
From McKinney
Copyright © 2018 Corbin Russwin, Inc., an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the
express written permission of Corbin Russwin, Inc. is prohibited.
5) Wiring Diagrams (Continued)
MODE 1: LED WIRE NOT USED = RED LED 'ON' WHEN POWERED
12/24VDC System
• Reader Draw = 150mA @12VDC / 24VDC
• Actuator Draw = 400mA inrush / 15mA continuous @12VDC / 24VDC
• Total System Draw = 550mA @12VDC / 24VDC
QC12 Electric
Hinge From
McKinney
*IMPORTANT: Pin 7 must be tied to earth ground in the access control panel.
Failure to follow proper ESD safe grounding procedures could lead to equipment failure.
Lockbody
Power Supply
120 VAC
(By Others)
Input
READER NEG - Black, 1
READER POS - Red, 2
DATA 1 - White, 3
DATA 0 - Green, 4
RX (NO) - Orange, 5
RX (COM) - Blue, 6
*EARTH GROUND - Brown, 7
LED - Yellow, 8
Not Used
LOCK NEG - Violet, 9
LOCK POS - Gray, 10
DPS (NC) - Pink, 11
DPS (COM) - Tan, 12
5
H
N
G
Access 600 Reader Electronics
Require 12 or 24VDC UL294 Listed,
24VDC
Power Limited Power Supply (or UL603)
-
+
ULC-S319 compliance:
EAC power supply utilizing battery backup
(30 minutes operation) is required.
Access 600 Series M812
-
12/24VDC
+
DATA 1
DATA 0
RX (NO)
(By Others)
RX (COM)
Use (NC)
For Fail Safe
Operation
Lock
Relay
DPS
DPS
(NO) Fail
Secure
Operation
UL294 Listed EAC Panel
Electrical
Access
Control
Panel