ED5200N Series Exit Devices
8) Surface Vertical Rod Installation Instructions (Continued)
6 Install Mounting Plate and Controller
Pass the ElectroLynx harness through center hole of mounting plate (Fig. 6A) to make the
following connections:
Important
: Connections are made along side, not behind center hole of bracket.
a. Connect P5 (7 Pin Connector) from reader board to J5 on interior escutcheon PCB assembly (Fig. 6A).
2
1
P5
b. Connect ElectroLynx harness (4 and 8-pin) from door harness to ElectroLynx harness on interior
PCB assembly (Fig. 6B).
• Connectors go on only one way - do not offset
connector and be sure they are completely
seated.
• Do not tuck excess wires back inside the lock
body cylinder hole.
• Neatly fold the wires into the remaining space
to prevent pinching wires when mounting
escutcheon.
c. Attach the mounting plate to the mounting bracket
using (2) mounting plate screws (Fig 6B).
c. Secure (pin 5) green/yellow ground wire ring terminal
to screw immediately above the 'UP' arrow.
e. Secure (pin 7) ground wire (from reader) to lower left
screw of mounting bracket
Copyright © 2018 Corbin Russwin, Inc., an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the
express written permission of Corbin Russwin, Inc. is prohibited.
P
T O
1
Fig. 6A
15
J2
J1
P5
Fig. 6B
Mounting Bracket
Mounting Plate
(2) Mounting
Plate Screws
3
4
2
5