AUMA SA Series Operating Instructions Manual page 90

Multi-turn actuators
Hide thumbs Also See for SA Series:
Table of Contents

Advertisement

Technical data
Service conditions
Use
Mounting position
Installation altitude
Ambient temperature
Humidity
Enclosure protection according to
EN 60529
Pollution degree according to IEC
60664-1
Vibration resistance according to
IEC 60068-2-6
Corrosion protection
Coating
Colour
Accessories
Wall bracket
Programming software
Torque measurement flange DMF
Further information
Weight
EU Directives
90
SA 07.2
SA 16.2 / SAR 07.2
Indoor and outdoor use permissible
Any position
≤ 2 000 m above sea level
> 2,000 m above sea level, on request
Refer to name plate of actuator controls
Up to 100 % relative humidity across the entire permissible temperature range
Standard:
IP68
M12 connection: IP67
Option:
Terminal compartment additionally sealed against interior of actuator controls (double
sealed)
According to AUMA definition, enclosure protection IP68 meets the following requirements:
Depth of water: Maximum 8 m head of water
Duration of continuous immersion in water: Maximum 96 hours
Up to 10 operations during continuous immersion
Modulating duty is not possible during continuous immersion.
For exact version, refer to actuator controls name plate.
Pollution degree 4 (when closed), pollution degree 2 (internal)
Resistance against vibration can be given on request
Standard:
KS: Suitable for use in areas with high salinity, almost permanent condensation, and high
pollution.
Option:
KX: Suitable for use in areas with extremely high salinity, permanent condensation, and
high pollution.
Double layer powder coating
Two-component iron-mica combination
Standard:
AUMA silver-grey (similar to RAL 7037)
Option:
Available colours on request
For actuator controls mounted separately from the actuator, including plug/socket connector.
Connecting cable on request.
Recommended for high ambient temperatures, difficult access, or in case of heavy vibration during
service.
Cable length between actuator and actuator controls is max. 100 m (not suitable for version with poten-
tiometer in the actuator). Instead of the potentiometer, an MWG has to be used. (MWG requires separate
data cable.)
AUMA CDT (Commissioning and Diagnostic Tool for Windows-based PC)
AUMA Assistant App (Commissioning and Diagnostic Tool for Android devices)
Accessory for torque measurement for SA/SAR 07.2
Approx. 7 kg (with AUMA plug/socket connector)
Electromagnetic Compatibility (EMC): (2014/30/EU)
Low Voltage Directive: (2014/35/EU)
Machinery Directive: (2006/42/EC)
SAR 16.2 Control unit: electronic (MWG)
AC 01.2 Non-Intrusive EtherNet/IP
SA/SAR 16.2

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents