AUMA SA Series Operating Instructions Manual page 10

Multi-turn actuators
Hide thumbs Also See for SA Series:
Table of Contents

Advertisement

Identification
Type designation
Order number
Actuator serial number
Actuator terminal plan
AUMA power class for
switchgear
Control
Data Matrix code
10
SA 07.2
SA 16.2 / SAR 07.2
Descriptions referring to name plate indications
Figure 5: Type designation (example)
1.
Type and size of actuator
2.
Flange size
Type and size
These instructions apply to the following devices types and sizes:
SA.....= Type = Multi-turn actuator for open-close duty
Sizes and generation: 07.2, 07.6, 10.2, 14.2, 14.6, 16.2
SAR.... = Type = Multi-turn actuator for modulating duty
Sizes and generation: 07.2, 07.6, 10.2, 14.2, 14.6, 16.2
AC = Type = AC actuator controls
Size and generation: 01.2
The product can be identified using this number and the technical data as well as
order-related data pertaining to the device can be requested.
Please always state this number for any product inquiries.
On the Internet at http://www.auma.com > Service & Support > myAUMA, we offer
a service allowing authorised users to download order-related documents such as
wiring diagrams and technical data (both in German and English), inspection certificate
and the operation instructions when entering the order number.
Table 2:
Description of serial number (example of 0519MD12345)
05
19
MD12345
05
Positions 1+2: Assembly in week = week 05
19
Positions 3+4: Year of manufacture = 2019
MD12345
Internal number for unambiguous product identification
Position 9 after TPA: Position transmitter version
I, Q = MWG (magnetic limit and torque transmitter)
The switchgear used in the actuator controls (reversing contactors/thyristors) are
classified according to AUMA power classes (e.g. A1, B1, ....). The power class
defines the max. permissible rated power (of the motor) the switchgear has been
designed for. The rated power (nominal power) of the actuator motor is indicated in
kW on the motor name plate. For the assignment of the AUMA power classes to the
nominal power of the motor types, refer to the separate electrical data sheets.
For switchgear without assignment to any power classes, the actuator controls name
plate does not indicate the power class but the max. rated power in kW.
Table 3:
Control examples (indications on actuator controls name plate)
Input signal
Description
EtherNet/IP
Control via EtherNet/IP interface
EtherNet/IP/24 V DC
Control via EtherNet/IP interface and control voltage for OPEN - CLOSE
control via digital inputs (OPEN, STOP, CLOSE)
When registered as authorised user, you may use our AUMA Assistant App to scan
the Data Matrix code and directly access the order-related product documents without
having to enter order number or serial number.
SAR 16.2 Control unit: electronic (MWG)
AC 01.2 Non-Intrusive EtherNet/IP