Function

Fixed Value

Output Mode
Laser Emission
Control
% E
E # R
Example
(1) Read setting content (shown with BCC omitted).
If the timing operation is "Operation during open circuit".
(2) Change the setting (shown with BCC omitted).
Set the input mode on "Independent Input".
%
E E # W I M 3 0
Command
Setting
Code
Code
Read
Set
C
3
R
C
R
C
R
6-24
CHAPTER 6 RS-232C CONTROL
Content
0
Hold
1
0
+10.9V, 29.5mA
1
-10.9V, 0mA
OFF, 1, 2, 3, 4, 5, 6, 7, 8,
9, 10, 11, 12, 13, 14, 15
(times)
0
OFF
1
ON
0
circuit
1
circuit
Measurement value at
0
the last time
1
Fixed value: max.
2
Fixed value: zero
3
Fixed value: min.
0
Independent Input
1
Lump Input
0
Normal
1
Test
Beam emission stopped
0
at timing
Beam emission
1
continued at timing
%
Respond
%
E E
$ R T M
1
C
R
%
E E
$ W I M
C
R
C
3
R
BCC