CHAPTER 2 INSTALLATION
Mutual Interference
If more than 1 sensor head is mounted close together, no mutual interference will occur if
the neighboring sensor's laser spot is outside the shaded portion in the figure below.
Mount other sensor heads so laser spots do not enter the shaded area.
When using 2 sensor heads connected to 1 controller, it is possible to use the interference
prevention function. Refer to 5-2-12, "Interference Prevention".
• 50mm type
• 85mm type
(Unit: mm)
2-8