Panasonic HL-C1 Series User Manual page 89

Ultra high-speed laser displacement sensor (ccd style)
Table of Contents

Advertisement

CHAPTER 5 FUNCTION ITEMS
5-2-21 Analog Output Setting
This function causes the output to correspond to the desired measurement at an analog
output of +5V (20mA) and at -5V (4mA). It can be used to scale analog output or increase
or decrease output, etc.
When this function is used, the analog output corresponding to measurements ranging
between 70 and 90mm, for example, can be assigned an output ranging from -5V (for 70mm)
to +5V (for 90mm).
1. Display the input/output screen.
Touch
on the MENU Screen and display the input/output
screen.
2. Display the analog output screen.
Touch
analog output screen.
3. Display the output setting screen.
Touch
measurement setting corresponding to +5V (20mA) and a
keyboard for inputting numbers are displayed.
The value is for sensor head 1 (H1) in independent operation,
and it is the value corresponding to the add/subtract calculation
value (AS: ADD/SUB) in add/subtract operation.
4. Set measurement which +5V is to correspond to.
See page 4-2 for keyboard input.
5. Set measurement which -5V is to correspond to.
Touch
on the +5V value screen and display the currently set
measurement corresponding to -5V (4mA) and the keyboard.
The value is for sensor head 1 in independent operation, and
corresponds to the add/subtract calculation value in add/subtract
operation.
on the input/output screen and display the
on the analog output screen. The current
5-29
MENU Screen
Input/output Screen
Analog Output Screen
+5V Value Screen
+5V Value Screen
-5V Value Screen