Section 5
Printer Tests
Online Tests
Refer to the Total Online Test System (TOLTS) Reference Manual, Order
No. DD39, and the Total Online Test System (TOLTS) Test Pages , Order
No. DD49.
Offline Tests
There are two offline tests available to the operator: the power-on test and the
print test.
Power-On Test
When the printer is powered up (i.e., the circuit breakers are closed), two dots
are lit on the control panel display after which the microprocessor interface
(MPl) runs the MPI self-test. When the self-test is finished, 00 is displayed to
indicate no error. Any other code displayed after power up indicates an error.
Refer to Appendix A.
Print Test
In offline mode, set the PRINT TEST. The test consists of print and skip
sequences using the 6 and 8 lines per inch skip modes and the 4 and 6 meters
per second belt speeds if this option is installed. The test is interrupted by
pressing the STOP push button on the control panel.