2.7.3 Live data (5-3)

This function can be used to study an Automower in
operation. Using Live data you receive relevant data
for respective component groups or function.
Select a group and start the Automower. A group of
values (data) are shown on the display when the
mower is working. See 2.7.2 Test (5-2), page 35 for
more information about the different values. Press
Arrow back to exit.

Blade motor (5-3-1)

Current, average current, speed and voltage are
shown.

Wheel motors (5-3-2)

Power L, power R, pulse difference and speed are
shown.

Battery (5-3-3)

Voltage, charge, current and battery temperature are
shown.

Loop (5-3-4)

Values for the loop signals, quality and restart are
shown.

Sensors (5-3-5)

Positions for the collision sensors, lift sensor and tilt
sensor are shown.

Customized (5-3-6)

Customized is a function to determine which four
values are to be shown on the display when real time
data is started. However, the function does not need to
be use other than on the direct request of
Husqvarna AB.

2.7.4 Demo mode (5-4)

The function is only available for 220 AC. In demo
mode the Automower works without starting the blade
disc. The mower varies running with charging at four
minute intervals.
The checkbox is checked when ON is selected.
40 - English
2. SPECIAL MENU FUNCTIONS
Operating history
Test
Live data
Demo mode
Loop detection
Special settings
5-3
Operating history
Test
Live data
Demo mode
Loop detection
Special settings
5-4
Blade motor
Wheel motors
Battery
Loop
Sensors
Customized
5-3-
ON
OFF
5-4-

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents