Beckhoff C33-0060 Series Installation And Operating Instructions Manual

Advertisement

Quick Links

Installation and Operating instructions for
Build-in Industrial PC
C33xx from -0060
Version: 3.0
Date:
2020-04-23

Advertisement

Table of Contents
loading

Summary of Contents for Beckhoff C33-0060 Series

  • Page 1 Installation and Operating instructions for Build-in Industrial PC C33xx from -0060 Version: 3.0 Date: 2020-04-23...
  • Page 3: Table Of Contents

    Description of the keys Function keys Special keys Maintenance Cleaning the Industrial PC Replacing the battery on the motherboard Servicing Shutting down Disposal Troubleshooting Fault correction Beckhoff Support and Service Beckhoff branches and partner companies Beckhoff company headquarters Beckhoff Support Beckhoff Service C33xx...
  • Page 4 Foreword Assembly dimensions Appendix Technical data Approvals FCC: Federal Communications Commission Radio Frequency Interference Statement FCC: Canadian Notice C33xx...
  • Page 5: Foreword

    Beckhoff Automation GmbH & Co.KG. Delivery conditions In addition, the general delivery conditions of the company Beckhoff Automation GmbH & Co.KG apply. C33xx...
  • Page 6: Description Of Safety Symbols

    Foreword Description of safety symbols The following safety symbols are used in this operating manual. They are intended to alert the reader to the associated safety instructions. This symbol is intended to highlight risks for the life or health of personnel. Danger This symbol is intended to highlight risks for equipment, materials or the environment.
  • Page 7: Basic Safety Measures

    Foreword Basic safety measures Only switch the PC off after Before the Industrial PC is switched off, software that is running must closing the software be properly closed. Otherwise it is possible that data on the hard disk is lost. Please read the section on Switching the Industrial PC on and off.
  • Page 8: Operator's Obligation To Exercise Diligence

    Foreword Operator’s obligation to exercise diligence The operator must ensure that • the Industrial PC is only used for its intended use (see also chapter Product Description). • the Industrial PC is in a sound condition and in working order during operation.
  • Page 9: Product Description

    Product Description Product Description Appropriate Use The C33xx Industrial PC is designed for mounting in control cabinets for machine and plant engineering applications. In addition to the PC with standard ATX-motherboard, a hard disk, floppy disk drive, machine-fair keyboard and a TFT display are integrated in a 19 inch rack. Structure Lockable front flap There is a lockable front flap above the display, behind which a floppy disk...
  • Page 10 Product Description Internal view of the PC Behind the front door (1) is a 7 slot computer core with standard ATX motherboard (2) and power supply unit (3). Removing the drives The drives (1, 2) can be removed without using any tool. After removing the card holder the plug-in cards (3) can be remoted.
  • Page 11 Product Description Connections of the Industrial PC The illustration shows the assembly of the PC (1) with excerpt frameworks (2) and telescope rails (3). The interface connections are at the side of the housing (4). Connections behind the The connections for the mouse (1) and the front flap keyboard (2) are located behind the front flap.
  • Page 12: Interfaces From C33Xx-0060

    Product Description Interfaces from C33xx-0060 ATX motherboard interfaces PS/2 connections PS/2 The upper PS/2 connector (X104) allows a PS/2 mouse to be used, while a PC keyboard can be connected to the lower PS/2 connector (X103). USB interfaces USB1 – USB4 The four USB interfaces (X108 –...
  • Page 13: Installation Instructions

    4. Please keep the associated paperwork. It contains important information for handling the unit. 5. Check the contents for visible shipping damage. 6. If you notice any shipping damage or inconsistencies between the contents and your order, you should notify Beckhoff Service. C33xx...
  • Page 14: Installation Of The Pc In The Control Cabinet

    Installation Instructions Installation of the PC in the control cabinet The C33xx Industrial PC is designed for mounting in control cabinets for machine and plant engineering applications. The ambient conditions specified for operation must be observed (see chapter Technical data). Preparation of the control Four holes for the fixing bolts have to be provided in the control cabinet cabinet...
  • Page 15: Power Supply Connection

    Installation Instructions Power Supply Connection The 5-pin CAGE CLAMP plug connector and mounting flange illustrated is located on the PC housing in order to connect the power supply. Socket at the PC housing Technical data Connecting socket Number of contacts Contact spacing 5 mm Minimum conductor cross-section...
  • Page 16: Differently Coded Connectors

    Installation Instructions Differently coded Connectors Coding pieces The connectors are coded differently at the factory, using snap-on coding pieces, according to the power supply unit that has been fitted. Differently coded plug connectors Coding for the 100-240 V Coding for the 24 V power supply 50-60 Hz power supply unit unit...
  • Page 17 Installation Instructions Pin assignment and cable requirements Pin assignment There is an adhesive label with the pin assignments on the top of the female plug connector. The minimum permitted conductive cross- section is 1.5 mm², fused for 10 A (AWG 16). Industrial PCs with 100-240 V , 50-60 Hz power supply unit Pin assignment for the...
  • Page 18: Connecting Power Supply

    Installation Instructions 5. Fix the upper part (part B) of the strain relief housing by snapping it onto the lower part. Connecting Power Supply The external wiring consists of the connection of the power supply, the battery pack (optional) and the connection of customized components for shutting down the PC.
  • Page 19: Wiring Diagram

    Installation Instructions Wiring diagram Wiring according to the wiring diagram (the circuit of PC_ON and Power- Status is symbolical): Wiring diagram external switch and power supply Connection of the Battery Pack and UPS Output only in combination with integrated UPS (order option). C33xx...
  • Page 20: Connecting Devices

    Installation Instructions Connecting devices The power supply plug must be withdrawn! Warning Please read the documentation for the external devices prior to connecting them. During thunderstorms, plug connector must neither be inserted nor removed. When disconnecting a plug connector, always handle it at the plug. Do not pull the cable! Connecting cables The connections are located at the side of the Industrial PC and at the rear...
  • Page 21: Operating Instructions

    Operating Instructions Operating Instructions Please also refer to chapter Appropriate Use. Switching the Industrial PC on and off Switch on The Industrial PC does not have its own mains switch. The Industrial PC will start when the equipment is switched on, or when it is connected to the power supply.
  • Page 22: Operating The Industrial-Pc

    Operating Instructions Operating the Industrial-PC Type-dependent number of Depending on the precise type, the Industrial PC can have fewer keys than keys those described here. Description of the keys Operation The cursor is the blinking character that marks the point at which the next character entered will be displayed.
  • Page 23: Function Keys

    Operating Instructions The Esc key has the effect of closing dialog windows and of interrupting some of the computer’s working operations. All other keys bring the character printed on them onto the display at the position of the cursor. Function keys The meaning of the function keys, F1 to F10, is determined by the software and is displayed at the bottom edge of the display.
  • Page 24: Maintenance

    Operating Instructions Maintenance Please also refer to chapter Appropriate Use. Cleaning the Industrial PC Switch off the Industrial PC and all connected devices, and disconnect the Industrial PC from the power supply. Danger The Industrial PC can be cleaned with a soft, damp cloth. Do not use any aggressive cleaning materials, thinners, scouring material or hard objects that could cause scratches.
  • Page 25: Troubleshooting

    Nothing happens after the Industrial No power supply to the Industrial Check power supply cable. PC has been switched on Other cause. Call Beckhoff Service. The Industrial PC does not boot Floppy disk or CD in the drive. Remove floppy disk or CD fully and press any key.
  • Page 26: Beckhoff Support And Service

    Please contact your Beckhoff branch office or partner company for local support and service on Beckhoff products! The contact addresses for your country can be found in the list of Beckhoff branches and partner companies: www.beckhoff.com You will also find further documentation for Beckhoff components there.
  • Page 27 Assembly dimensions Assembly dimensions The following pages show diagrams of the Industrial PCs, with dimensions in mm. The assembly of the unit must take place with the orientation diagrammed here. Warning Industrial-PC C3320 screw mounting M3x10 through- hole for M4 screws screw mounting M3x10 front view...
  • Page 28 Assembly dimensions The assembly of the unit must take place with the orientation diagrammed here. Warning Industrial-PC C3330 screw mounting M3x10 through- hole for M4 screws screw mounting M3x10 front view side view plan view cut out for installation plan view with excerpt-frame for side view with excerpt-frame for front assembly front assembly...
  • Page 29 Assembly dimensions The assembly of the unit must take place with the orientation diagrammed here. Warning Industrial-PC C3340 screw mounting M3x10 through- hole for M4 screws screw mounting M3x10 side view front view plan view cut out for installation plan view with excerpt-frame for side view with excerpt-frame for front assembly front assembly...
  • Page 30 Assembly dimensions The assembly of the unit must take place with the orientation diagrammed here. Warning Industrial-PC C3350 screw mounting M3x10 through- hole for M4 screws screw mounting M3x10 front view side view cut out for installation plan view plan view with excerpt-frame for side view with excerpt-frame for front assembly front assembly...
  • Page 31 Appendix Appendix Technical data Industrial-PC C3320 Dimensions (W x H x D): 482.7 x 355 x 282 mm Weight: 18 kg (basic configuration) Industrial-PC C3330 Dimensions (W x H x D): 482.7 x 400 x 282 mm Weight: 18,5 kg (basic configuration) Industrial-PC C3340 Dimensions (W x H x D): 482.7 x 355 x 282 mm...