Differently Coded Connectors; Fitting The Power Supply Cable - Beckhoff C33-0060 Series Installation And Operating Instructions Manual

Table of Contents

Advertisement

Installation Instructions
Coding pieces
Differently coded plug
connectors
Materials for assembly of
the connector
Female plug connector is
correspondingly coded
14

Differently coded Connectors

The connectors are coded differently at the factory, using snap-on coding
pieces, according to the power supply unit that has been fitted.
Coding for the 100-240 V
50-60 Hz power supply unit

Fitting the Power Supply Cable

A 5-pin female plug connector with CAGE CLAMP connection and insertion
catches is supplied along with a snap-on strain relief housing in order to
assemble the PC power supply cable.
Female plug connector
This female plug connector is also coded at the factory, according to the
type of power supply fitted, so that the plug, when assembled, will fit the
Industrial PC's connecting socket.
Technical data
Number of contacts
Contact spacing
Minimum conductor cross-section
Minimum conductor cross-section
Rated voltage (EN)
Rated voltage (CSA)
Current (EN)
Current (CSA)
Length of stripped conductor
,
Coding for the 24 V
AC
unit
A
C
Strain relief housing
Female plug connector
5
5 mm
1.5
mm²
16
(AWG)
250 V
300 V
16 A
15 A
8 to 9 mm
power supply
DC
B
D
C33xx

Advertisement

Table of Contents
loading

This manual is also suitable for:

C33-0070 series

Table of Contents