Table of Contents

Advertisement

Quick Links

Manual | EN
C7015
Industrial PC
2022-3-30 | Version: 1.0

Advertisement

Table of Contents
loading

Summary of Contents for Beckhoff C7015

  • Page 1 Manual | EN C7015 Industrial PC 2022-3-30 | Version: 1.0...
  • Page 3: Table Of Contents

    Grounding of the Industrial PC .................. 31 4.3.2 Connecting cables and power supply ................ 32 Switching the Industrial PC on and off..................... 33 5 Beckhoff Device Manager ........................ 34 6 Decommissioning............................ 36 Disconnecting the power supply and cables ................... 36 Disassembly and disposal ....................... 37 7 Maintenance ............................. 39...
  • Page 4 Table of contents 10.1 Service and support......................... 44 10.2 Approvals............................ 45 Version: 1.0 C7015...
  • Page 5: Notes On The Documentation

    Copyright © Beckhoff Automation GmbH & Co. KG. Publication of this document on websites other than ours is prohibited. Offenders will be held liable for the payment of damages. All rights reserved in the event of the grant of a patent, utility model or design.
  • Page 6: For Your Safety

    Exclusion of liability Beckhoff shall not be liable in the event of non-compliance with this documentation and thus the use of the devices outside the documented operating conditions. Description of safety symbols The following safety symbols are used in these operating instructions.
  • Page 7: Fundamental Safety Instructions

    • the operating instructions are in good condition and complete, and always available for reference at the location where the products are used. C7015 Version: 1.0...
  • Page 8: Notes On Information Security

    For your safety Notes on information security The products of Beckhoff Automation GmbH & Co. KG (Beckhoff), insofar as they can be accessed online, are equipped with security functions that support the secure operation of plants, systems, machines and networks. Despite the security functions, the creation, implementation and constant updating of a holistic security concept for the operation are necessary to protect the respective plant, system, machine and networks against cyber threats.
  • Page 9: Product Overview

    Product overview Product overview The C7015 Industrial PC is an ultra-compact Industrial PC in IP65 that can be mounted either in the control cabinet to save space or directly on the machine. Thanks to the existing processors, the Industrial PC has sufficient performance reserves for the following applications, among others: •...
  • Page 10: Structure

    Product overview Structure Fig. 1: C7015_structure Table 1: Key - C7015 structure Component Description USB interfaces (X107, X108) Connection of peripheral devices Flexible mounting concept For mounting inside or outside the control cabinet via the rear or side panel EtherCAT P LEDs Display for Link Activity, system voltage, peripheral voltage...
  • Page 11: Interface Description

    Product overview Interface description In the basic configuration, the C7015 includes the following interfaces: • EtherCAT P (X101) • Power supply (X102) • Ethernet RJ45 (X103-X105) • Mini DisplayPort (X106) • USB (X107, X108) 3.2.1 EtherCAT P The Industrial PC has an EtherCAT P interface (X101). EtherCAT P (EtherCAT + Power) is an extension of the EtherCAT technology in the area of cabling.
  • Page 12: Power Supply

    Industrial PC, so that the Industrial PC remains switched on during voltage fluctuations. There is no voltage connector in the scope of delivery of the Industrial PC. For the connection of the PC Beckhoff recommends to buy a ready-made cable (see chapter 3.5 Connection cable and accessories [} 19]).
  • Page 13: Ethernet Rj45

    Since the LEDs directly at the interface cannot be seen with an existing wiring, the LEDs on the side panel of the PC (see Fig. 6) show the status of the Ethernet interfaces. LAN3 LAN2 LAN1 Fig. 6: C7015_Ethernet LEDs C7015 Version: 1.0...
  • Page 14: Mini Displayport

    The Industrial PC has a Mini DisplayPort according to IP65/67 (X106) that enables connection of devices with Mini DisplayPort. It facilitates transfer of image signals. In addition, DVI signals can be transferred via an adapter. Please get in touch with your Beckhoff sales contact.
  • Page 15: Usb

    The USB interfaces are electronically protected. X108 X107 Fig. 8: C7015_USB interfaces pin numbering Table 7: USB interface pin assignment Connection Shield Vbus StdA_SSRX - StdA_SSRX + GND_DRAIN StdA_SSTX - StdA_SSTX + C7015 Version: 1.0...
  • Page 16: Status Leds

    Table 8: Meaning of the UPS-OCT LED Color Flashing interval Meaning None Steadily lit No UPS-OCT connected Blue Flashing Bootloader active Yellow Steadily lit Moderate signal quality Green Steadily lit Good signal quality Steadily lit Poor signal quality Version: 1.0 C7015...
  • Page 17: Pwr Led

    Flashing Checksum error during the I2C transmission in the bootloader Cyan Flashing (2 s) contact Beckhoff Service 3.3.3 HDD LED The HDD LED indicates the activity of the storage medium. The colors and flashing intervals have the following meanings: Table 10: Meaning of the HDD LED...
  • Page 18: Name Plate

    The name plate provides information on the equipment fitted to the Industrial PC. xxxxxxxx xxxxxxxxxxxx xxxxxxxxxxxx xxxxxxxxxxxx Fig. 10: C7015_name plate Table 12: Key - C7015 name plate Description Manufacturer, including address Model: the last four digits indicate the product variant. Serial number (BTN) Date of manufacture...
  • Page 19: Connection Cable And Accessories

    Product overview Connection cable and accessories For the connection of your Industrial PC there are some ready-made cables available. The following ready-made cables can be ordered from your Beckhoff Sales. Table 13: Network cable Order number Network cable C9900-K948 Industrial Ethernet/EtherCAT cable, PUR, 4 x 2 x AWG26/7, fixed installation, green, Cat.6A, push-pull V4, RJ45, plug, straight, IP65/67, 8-pin - push-pull V4, RJ45, plug,...
  • Page 20 Cat.6A, push-pull V4, RJ45, plug, straight, IP65/67, 8-pin - RJ45, plug, straight, IP20, 40.00 m C9900-K969 Industrial Ethernet/EtherCAT cable, PUR, 4 x 2 x AWG26/7, fixed installation, green, Cat.6A, push-pull V4, RJ45, plug, straight, IP65/67, 8-pin - RJ45, plug, straight, IP20, 50.00 m Version: 1.0 C7015...
  • Page 21: Table 14 Usb Cables

    V4, USB-A, 3.0, plug, straight, IP65/67 - push-pull V4, USB-A, 3.0, plug, straight, IP65/67, 3.00 m C9900-K991 USB cable shielded, PVC, 2 x AWG26 + 2 x AWG24, fixed installation, black, push-pull V4, USB-A, 3.0, plug, straight, IP65/67 - push-pull V4, USB-A, 3.0, plug, straight, IP65/67, 5.00 m C7015 Version: 1.0...
  • Page 22: Table 15 Power Cable

    In the event that you carry out the assembly of the cables from the necessary individual parts yourself, you will need the following crimp tool from Harting: • HPP V4 Power Crimp Tool (order number: 09 46 800 0000) Version: 1.0 C7015...
  • Page 23: Table 17 Accessories

    Product overview You can order the following accessories from Beckhoff Sales: Table 17: Accessories Order number Accessories C9900-K935 Protection cap, plastic, push-pull V4, black, straight, IP65/67, 5 pcs. C9900-K936 Power plug, field assembly, plastic, 2.5mm², AWG14, push-pull V4, power, plug, black/...
  • Page 24: Commissioning

    5. Check the contents for visible shipping damage. 6. In case of discrepancies between the package contents and the order, or in case of transport damage, please inform Beckhoff Service (see Chapter 10.1 Service and support [} 44]). Version: 1.0 C7015...
  • Page 25: Assembly

    The mounting concept allows mounting via the rear panel as well as via the right side panel of the Industrial PC. The C7015 can either be mounted inside a control cabinet or integrated outside a control cabinet on the machine or plant.
  • Page 26: Dimensions

    The dimensions of the Industrial PC and the mounting concept are used to prepare the control cabinet and to mount the device correctly inside and outside the control cabinet. All dimensions are in mm. Figure 12 shows the dimensions of the C7015 with the flexible mounting concept. 32,5 Fig. 12: C7015_dimensions If you have mounted an EtherCAT P Box module directly on the Industrial PC, this changes the dimensions.
  • Page 27: Mounting The Industrial Pc

    If you have mounted an EtherCAT P Box module directly on the Industrial PC (see chapter 4.2.3 Mounting EtherCAT P Box module [} 29]), you can mount the Industrial PC with the module exclusively via the rear panel (see Fig. 15). C7015 Version: 1.0...
  • Page 28: Fig. 15 C7015_Mounting With Ethercat P Box Module

    Commissioning Fig. 15: C7015_Mounting with EtherCAT P Box module Version: 1.0 C7015...
  • Page 29: Mounting Ethercat P Box Module

    The integrated EtherCAT P connection of the Industrial PC enables you to connect actuators/sensors directly via IP67-protected EtherCAT P Box modules. These act as EtherCAT P slaves, while the C7015 is used as master. For more information on the Box modules, refer to the EPP1xxx documentation.
  • Page 30: Connecting The Industrial Pc

    Devices connected to the Industrial PC with their own power supply must have the same potential for the PE and "0 V" conductors as the Industrial PC (no potential difference). 230 V 24 V Grounding busbar Fig. 18: C7015_wiring example Version: 1.0 C7015...
  • Page 31: Grounding Of The Industrial Pc

    The functional earth is necessary for the EMC of the device. The functional earthing is also established via the earthing connection between the protective conductor connection on the device and the central grounding point of the control cabinet in which the PC is installed. C7015 Version: 1.0...
  • Page 32: Connecting Cables And Power Supply

    2. Plug the power cable into the 4-pin push-pull built-in power socket of the Industrial PC. 3. Connect the PC to your external 24 V power supply. 4. Switch on the 24 V power supply. 5. Measure the voltage on the power supply plug of the PC. Version: 1.0 C7015...
  • Page 33: Switching The Industrial Pc On And Off

    When you switch on the Industrial PC for the first time, the pre-installed operating system (optional) will be started. For any additional hardware you have connected, you have to install the drivers yourself afterwards. In addition, the Beckhoff Device Manager starts automatically. The Device Manager is a software from Beckhoff that supports you in configuring the PC.
  • Page 34: Beckhoff Device Manager

    • User name: Administrator • Password: 1 You also have the option of using the Beckhoff Device Manager to remotely configure the Industrial PC via a web browser. More detailed information is available in the Beckhoff Device Manager manual. First start Beckhoff Device Manager When your Industrial PC is booted for the first time, the Beckhoff Device Manager also starts automatically for the first time.
  • Page 35: Fig. 20 Beckhoff Device Manager - Start Page

    Secure passwords Strong passwords are an important prerequisite for a secure system. Beckhoff supplies the device images with standard user names and standard passwords for the operating system. It is imperative that you change these. Controllers are shipped without a password in the UEFI/BIOS setup. Beckhoff recommends assigning a password here as well.
  • Page 36: Decommissioning

    To disconnect the cables from the Industrial PC, proceed as follows: 1. Make a note of the wiring configuration, if you wish to restore it with another device. 2. Disconnect the data transmission cables from the Industrial PC. 3. Finally, disconnect the ground connection. Version: 1.0 C7015...
  • Page 37: Disassembly And Disposal

    2. Remove the module (section B). 3. Loosen the four M5x16 screws that secure the mounting rail to the side panel of the PC (section C). 4. Remove the mounting rail (section D). ð You have disassembled the EtherCAT P Box module. C7015 Version: 1.0...
  • Page 38: Fig. 22 C7015_Disassembly Ethercat P Box Module

    • Send plastic parts (polycarbonate, polyamide (PA6.6)) for plastics recycling. • Take metal parts to the metal recycling collection point. • Electronic parts such as circuit boards must be disposed of in accordance with national electronics scrap regulations. Version: 1.0 C7015...
  • Page 39: Maintenance

    Repair Only the manufacturer may repair the device. If a repair should be necessary, contact Beckhoff Service (see Chapter 10.1 Service and support [} 44]). Cleaning...
  • Page 40: Table 18 Replacement Recommendations For Pc Components

    Maintenance Maintenance Beckhoff Industrial PCs are manufactured from components of the highest quality and robustness. They are selected and tested for best interoperability, long-term availability and reliable function under the specified environmental conditions. Nevertheless, some components of the Industrial PC may be subject to a limited service life if they are operated under certain conditions, such as more demanding ambient conditions during operation or during storage, or if they are out of service for long periods of storage.
  • Page 41 • Only remove new electronic components from the ESD packaging (tinted plastic bag) after putting on the wrist grounding strap. • Do not walk around with electronic components in your hand if they are not in ESD packaging. C7015 Version: 1.0...
  • Page 42: Troubleshooting

    Nothing happens after the Missing power supply of the Check the power supply cable Industrial PC has been switched on Industrial PC Call Beckhoff Service Other cause The Industrial PC does not boot Setup settings are incorrect Check the setup settings...
  • Page 43: Technical Data

    Technical data Technical data Table 20: Technical data Product designation C7015 Dimensions (W x H x D) 85 x 167 x 43 mm, without mounting plate Weight approx. 1000 g Supply voltage 20.4-30 V (24 V power supply unit, NEC class 2) Power consumption Without EPP: max.
  • Page 44: Appendix

    Telephone: + 49 (0) 5246/963-0 Fax: + 49 (0) 5246/963-198 email: info@beckhoff.de The addresses of the worldwide Beckhoff branches and agencies can be found on our website at http:// www.beckhoff.com/. You will also find further documentation for Beckhoff components there.
  • Page 45: Table 21 Approvals C7015

    Appendix 10.2 Approvals The following table shows the approvals of the Industrial PC based on the device generation: Table 21: Approvals C7015 Device generation Approvals C7015-0020 CE, EAC, UKCA, FCC You will find all other applicable approvals on the name plate of your device.
  • Page 46 C7015_EtherCAT P Box module mounted .................. Fig. 18 C7015_wiring example ........................ Fig. 19 Beckhoff Device Manager - Change passwords................Fig. 20 Beckhoff Device Manager – Start page ..................Fig. 21 C7015_Disassembly with mounting concept ................Fig. 22 C7015_Disassembly EtherCAT P Box module................Version: 1.0...
  • Page 47 Table 9 Meaning of the PWR LED......................Table 10 Meaning of the HDD LED ......................Table 11 Meaning of the TC LED ....................... Table 12 Key - C7015 name plate ......................Table 13 Network cable ..........................Table 14 USB cables ..........................
  • Page 49 More Information: www.beckhoff.com/C7015/ Beckhoff Automation GmbH & Co. KG Hülshorstweg 20 33415 Verl Germany Phone: +49 5246 9630 info@beckhoff.com www.beckhoff.com...

Table of Contents